A Closed-Form Topological Supervisory Filter for Real-Time Voltage Collapse Prevention and Dynamic Capacity Routing in Radial Distribution Grids

Conventional continuation power flow and Newton-Raphson solvers scale cubically with network dimension and exhibit severe Jacobian ill-conditioning near saddle-node bifurcation boundaries. In distribution networks hosting high penetrations of volatile distributed energy resources and battery energy storage systems (BESS), millisecond-scale latency is required to trigger corrective load-shedding and rerouting. In this paper, we adapt the combinatorial mechanics of the Topological Discrete Universe (TDU v4.9) framework into a deterministic, closed-form macro-controller. The effective branch saturation u = S/S_max is mapped onto a bounded topological stress functional Sigma(u) possessing an analytical bifurcation limit at u_c = 1 / (1 + sqrt(delta_EMT)) ~ 0.7359. Evaluated on the benchmark IEEE 33-bus radial system, the proposed filter executes in 2.5 µs per decision cycle—representing an over 180x speedup compared to standard iterative solvers—and provides an early trigger threshold u_trigger ~ 0.6034 that precedes physical voltage collapse without matrix inversion.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-05
DOI
https://doi.org/10.5281/zenodo.23966168
Primary Topic
Optimal Power Flow Distribution
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Closed-Form Topological Supervisory Filter for Real-Time Voltage Collapse Prevention and Dynamic Capacity Routing in Radial Distribution Grids

Ján Otčenáš
Zenodo (CERN European Organization for Nuclear Research)
Optimal Power Flow Distribution
preprint

A Closed-Form Topological Supervisory Filter for Real-Time Voltage Collapse Prevention and Dynamic Capacity Routing in Radial Distribution Grids

Ján Otčenáš
preprint en

Abstract

Conventional continuation power flow and Newton-Raphson solvers scale cubically with network dimension and exhibit severe Jacobian ill-conditioning near saddle-node bifurcation boundaries. In distribution networks hosting high penetrations of volatile distributed energy resources and battery energy storage systems (BESS), millisecond-scale latency is required to trigger corrective load-shedding and rerouting. In this paper, we adapt the combinatorial mechanics of the Topological Discrete Universe (TDU v4.9) framework into a deterministic, closed-form macro-controller. The effective branch saturation u = S/S_max is mapped onto a bounded topological stress functional Sigma(u) possessing an analytical bifurcation limit at u_c = 1 / (1 + sqrt(delta_EMT)) ~ 0.7359. Evaluated on the benchmark IEEE 33-bus radial system, the proposed filter executes in 2.5 µs per decision cycle—representing an over 180x speedup compared to standard iterative solvers—and provides an early trigger threshold u_trigger ~ 0.6034 that precedes physical voltage collapse without matrix inversion.

Zenodo (CERN European Organization for Nuclear Research)
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon