X-Ray Computed Tomography and Laminography Measurements of a 3D-Stacked IC

Advanced semiconductor packages manufactured using heterogeneous integration techniques challenge many conventional non-destructive testing processes. A three-dimensional (3D) structure of stacked integrated circuits (ICs), for example, complicates many existing non-destructive testing techniques. X-ray-based imaging methods, on the other hand, can fully penetrate the part and are ideal for visualizing the complex 3D heterogeneity. In this research, two related X-ray-based 3D imaging techniques, X-ray computed tomography (XCT) and X-ray computed laminography (XCL), are used to measure over-molded modules on a laminate substrate that includes stacked flip-chip Gallium Nitride on Silicon Carbide (GaN-on-SiC) dies. Differences between XCT instruments, XCT instruments versus an XCL instrument, and acquisition parameter settings on 3D reconstructions of the sample are explored. Reference measurement results are compared for image quality, acquisition time, and imaging artifacts. We discuss the current capabilities, limitations, and a potential outlook/roadmap for improving throughput for these types of instruments.

Authors

Institutions

Publication Details

Journal
IMAPSource Proceedings
Published
2026-11-05
DOI
https://doi.org/10.4071/001c.173628
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

X-Ray Computed Tomography and Laminography Measurements of a 3D-Stacked IC

Adam L. Pintar, Felix Hoyean Kim, John Henry J. Scott, Jessie Zhang et al.
IMAPSource Proceedings
Advanced X-ray Imaging Techniques
article

X-Ray Computed Tomography and Laminography Measurements of a 3D-Stacked IC

Adam L. Pintar, Felix Hoyean Kim, John Henry J. Scott, Jessie Zhang, Orion Kafka, John A. Wu, Navid Asadizanjani, Istiaq F. Shiam
article en

Abstract

Advanced semiconductor packages manufactured using heterogeneous integration techniques challenge many conventional non-destructive testing processes. A three-dimensional (3D) structure of stacked integrated circuits (ICs), for example, complicates many existing non-destructive testing techniques. X-ray-based imaging methods, on the other hand, can fully penetrate the part and are ideal for visualizing the complex 3D heterogeneity. In this research, two related X-ray-based 3D imaging techniques, X-ray computed tomography (XCT) and X-ray computed laminography (XCL), are used to measure over-molded modules on a laminate substrate that includes stacked flip-chip Gallium Nitride on Silicon Carbide (GaN-on-SiC) dies. Differences between XCT instruments, XCT instruments versus an XCL instrument, and acquisition parameter settings on 3D reconstructions of the sample are explored. Reference measurement results are compared for image quality, acquisition time, and imaging artifacts. We discuss the current capabilities, limitations, and a potential outlook/roadmap for improving throughput for these types of instruments.

IMAPSource ProceedingsVol. 2026(Symposium)
National Institute of Standards and Technology (US), Georgetown University (US), University of Florida (US), QuesTek (United States) (US)
Openalex Percentile: Top 15%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon