Thermodynamic Modeling of Refrigerant Cycle in an Air-Source Heat Pump Boiler and Performance Validation

Building electrification has driven growing interest in domestic hot water (DHW) systems based on air-source heat pump boilers (ASHPBs). However, heat pump performance regression models based on manufacturer-specific data have limited applicability to alternative refrigerants and off-design conditions. This study develops a physics-based dynamic ASHPB model that couples a thermodynamic analysis of the refrigerant cycle with the effectiveness-number of transfer units (ε-NTU) method and incorporates an optimization routine to determine the refrigerant evaporation and condensation temperatures that minimize total power input. The model performance is validated against manufacturer data over leaving water temperatures of 40-65℃ and outdoor air temperatures of -10 to 30℃. The results show satisfactory agreement, with a mean absolute percentage error (MAPE) of 10.1% and a mean absolute error (MAE) of 0.35 for the coefficient of performance (COP). The proposed framework thus supports the manufacturer-independent evaluation of heat pump systems without relying on proprietary empirical curve fits.

Authors

Publication Details

Journal
설비공학논문집
Published
2026-11-06
DOI
https://doi.org/10.6110/kjacr.2026.38.11.608
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermodynamic Modeling of Refrigerant Cycle in an Air-Source Heat Pump Boiler and Performance Validation

Habin Jo, Wonjun Choi
설비공학논문집
Refrigeration and Air Conditioning Technologies
article

Thermodynamic Modeling of Refrigerant Cycle in an Air-Source Heat Pump Boiler and Performance Validation

Habin Jo, Wonjun Choi
article en

Abstract

Building electrification has driven growing interest in domestic hot water (DHW) systems based on air-source heat pump boilers (ASHPBs). However, heat pump performance regression models based on manufacturer-specific data have limited applicability to alternative refrigerants and off-design conditions. This study develops a physics-based dynamic ASHPB model that couples a thermodynamic analysis of the refrigerant cycle with the effectiveness-number of transfer units (ε-NTU) method and incorporates an optimization routine to determine the refrigerant evaporation and condensation temperatures that minimize total power input. The model performance is validated against manufacturer data over leaving water temperatures of 40-65℃ and outdoor air temperatures of -10 to 30℃. The results show satisfactory agreement, with a mean absolute percentage error (MAPE) of 10.1% and a mean absolute error (MAE) of 0.35 for the coefficient of performance (COP). The proposed framework thus supports the manufacturer-independent evaluation of heat pump systems without relying on proprietary empirical curve fits.

설비공학논문집Vol. 38(11)
Affordable and clean energy, Climate action
Openalex Percentile: Top 25%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Thermodynamic Modeling of Refrigerant Cycle in an Air-Source Heat Pump Boiler and Performance Validation — Habin Jo, Wonjun Choi · 설비공학논문집 (2026) | TGRS Research Map | TGRS