Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems

ABSTRACT Aim The glucose management indicator (GMI) estimates HbA1c from continuous glucose monitoring (CGM)‐derived mean glucose. We assessed whether this relationship differs between contemporary CGM systems. Materials and Methods In this observational study, mean sensor glucose was derived from 2 months of CGM data preceding HbA1c measurement in adults with Type 1 diabetes using Dexcom (Dx) G6/G7 ( n = 252) or Medtronic Guardian 4/Simplera (GSi) ( n = 180). Device‐specific GMI equations were derived using linear regression of measured HbA1c on mean sensor glucose and compared with the original GMI equation. For direct comparison of the Dx and GSi GMI equations, these GMI equations were combined, with 95% confidence intervals calculated using the delta method. Results The Dx GMI equation yielded statistically significantly lower GMI values compared with the original GMI equation at mean sensor glucose levels < 13.7 mmol/L, with increasing differences at lower glucose levels. Conversely, at mean sensor glucose levels above 8.3 mmol/L, the GSi GMI equation yielded statistically significantly higher GMI values than the original GMI equation, with increasing differences at higher glucose levels. The Dx and GSi device‐specific GMI equations yielded statistically significantly different GMI values > 6.7 mmol/L, with increasing differences at higher glucose levels. Conclusions The relationship between mean sensor glucose and HbA1c differed between contemporary CGM systems. This finding suggests that device‐specific GMI equations may improve interpretation of glycaemic control in the absence of standardisation across contemporary CGM systems.

Authors

Institutions

Publication Details

Journal
Diabetes Obesity and Metabolism
Published
2026-11-05
DOI
https://doi.org/10.1111/dom.71486
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems

Sara Heebøll, Christian Trolle, Morten Fenger‐Grøn, Katrine Bovién Gørlitz et al.
Diabetes Obesity and Metabolism
Diabetes Management and Research
article

Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems

Sara Heebøll, Christian Trolle, Morten Fenger‐Grøn, Katrine Bovién Gørlitz, Søren Gregersen, Sanne Fisker, Klavs Würgler Hansen
article en

Abstract

ABSTRACT Aim The glucose management indicator (GMI) estimates HbA1c from continuous glucose monitoring (CGM)‐derived mean glucose. We assessed whether this relationship differs between contemporary CGM systems. Materials and Methods In this observational study, mean sensor glucose was derived from 2 months of CGM data preceding HbA1c measurement in adults with Type 1 diabetes using Dexcom (Dx) G6/G7 ( n = 252) or Medtronic Guardian 4/Simplera (GSi) ( n = 180). Device‐specific GMI equations were derived using linear regression of measured HbA1c on mean sensor glucose and compared with the original GMI equation. For direct comparison of the Dx and GSi GMI equations, these GMI equations were combined, with 95% confidence intervals calculated using the delta method. Results The Dx GMI equation yielded statistically significantly lower GMI values compared with the original GMI equation at mean sensor glucose levels < 13.7 mmol/L, with increasing differences at lower glucose levels. Conversely, at mean sensor glucose levels above 8.3 mmol/L, the GSi GMI equation yielded statistically significantly higher GMI values than the original GMI equation, with increasing differences at higher glucose levels. The Dx and GSi device‐specific GMI equations yielded statistically significantly different GMI values > 6.7 mmol/L, with increasing differences at higher glucose levels. Conclusions The relationship between mean sensor glucose and HbA1c differed between contemporary CGM systems. This finding suggests that device‐specific GMI equations may improve interpretation of glycaemic control in the absence of standardisation across contemporary CGM systems.

Diabetes Obesity and Metabolism
Aarhus University (DK), Aarhus University Hospital (DK), Regional Hospital Central Jutland (DK), Steno Diabetes Center Aarhus (DK)
Openalex Percentile: Top 12%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon