Biomechanical comparison of crossed Kirschner wires fixation for supracondylar humerus fractures at different fracture lines: finite element analysis and exploration of the optimal fixed angle

Supracondylar humerus fractures(SHFs) are common in children, but the biomechanical stability of Kirschner wire (K-wire) fixation at different fracture levels has not been adequately investigated. This study aimed to compare the biomechanical characteristics of crossed K-wire fixation for SHFs with different fracture levels using finite element analysis (FEA) and to identify the optimal pin configuration, thereby providing a biomechanical basis for personalized surgical planning. A total of 27 types of finite element models were constructed, which showed different insertion angles of crossed K-wires based on the low fracture, the middle fracture, and the high fracture of SHFs. The equivalent (von Mises) stress, equivalent elastic strain, and total deformation were analyzed. The FEA results demonstrated distinct biomechanical characteristics across different fracture levels. For low fractures, smaller insertion angles for the crossed K-wires provided more favorable biomechanical performance. For middle fractures, a configuration combining a larger lateral insertion angle with a smaller medial insertion angle appeared to offer superior mechanical stability. For high fractures, crossed fixation using large insertion angles on both sides showed more favorable biomechanical characteristics. The study established a biomechanical relationship between fracture level and the optimal configuration of crossed K-wire fixation in SHFs. The findings can serve as a reference for optimizing the fixation techniques of the SHFs.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-11-05
DOI
https://doi.org/10.1186/s12891-026-10719-x
Primary Topic
Elbow and Forearm Trauma Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Biomechanical comparison of crossed Kirschner wires fixation for supracondylar humerus fractures at different fracture lines: finite element analysis and exploration of the optimal fixed angle

Yang Cao, Yue Guo, Yu Deng, Zhanpeng Guo et al.
BMC Musculoskeletal Disorders
Elbow and Forearm Trauma Treatment
article

Biomechanical comparison of crossed Kirschner wires fixation for supracondylar humerus fractures at different fracture lines: finite element analysis and exploration of the optimal fixed angle

Yang Cao, Yue Guo, Yu Deng, Zhanpeng Guo, Mina Huang, Yunlong Bi, Yansong Wang
article en

Abstract

Supracondylar humerus fractures(SHFs) are common in children, but the biomechanical stability of Kirschner wire (K-wire) fixation at different fracture levels has not been adequately investigated. This study aimed to compare the biomechanical characteristics of crossed K-wire fixation for SHFs with different fracture levels using finite element analysis (FEA) and to identify the optimal pin configuration, thereby providing a biomechanical basis for personalized surgical planning. A total of 27 types of finite element models were constructed, which showed different insertion angles of crossed K-wires based on the low fracture, the middle fracture, and the high fracture of SHFs. The equivalent (von Mises) stress, equivalent elastic strain, and total deformation were analyzed. The FEA results demonstrated distinct biomechanical characteristics across different fracture levels. For low fractures, smaller insertion angles for the crossed K-wires provided more favorable biomechanical performance. For middle fractures, a configuration combining a larger lateral insertion angle with a smaller medial insertion angle appeared to offer superior mechanical stability. For high fractures, crossed fixation using large insertion angles on both sides showed more favorable biomechanical characteristics. The study established a biomechanical relationship between fracture level and the optimal configuration of crossed K-wire fixation in SHFs. The findings can serve as a reference for optimizing the fixation techniques of the SHFs.

BMC Musculoskeletal Disorders
Jinzhou Medical University (CN)
Openalex Percentile: Top 11%
Elbow and Forearm Trauma Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon