Pulsed Discharge of a Lithium-Ion Cell in an Equivalent-Circuit Simulation: Effect of Peak Current and Pulse Period on Usable Capacity

Battery-powered cyber-physical devices often draw current in pulses, for example during radio transmission, and the effect of pulsing on the usable capacity is not obvious. This paper simulates a lithium-ion cell with a Thevenin equivalent circuit (nominal capacity 2.5 Ah, series resistance 60 mΩ, one RC branch with a time constant of 45 s) discharged to a 3.0 V cut-off with five current profiles. A constant 1 A load delivered 2.27 Ah, whereas pulsed loads with the same average current of 1 A (2 A at 50 % duty) delivered 2.17 Ah for a 10 s period and 2.16 Ah for a 120 s period. A 3 A / 33 % duty profile delivered 2.03 Ah. In the model, higher peak currents reach the voltage cut-off earlier because of larger resistive and polarisation voltage drops, leaving more charge unused. The cell parameters and the open-circuit-voltage curve are assumed, not measured. This is a simulation study; all results are outputs of the deposited Python code with assumed parameters. Source code is attached.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-05
DOI
https://doi.org/10.5281/zenodo.23983427
Primary Topic
Battery Modeling and Management
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Pulsed Discharge of a Lithium-Ion Cell in an Equivalent-Circuit Simulation: Effect of Peak Current and Pulse Period on Usable Capacity

Sahetnur Durdyyev, Umytbek Muradow, Yslam Orazov
Zenodo (CERN European Organization for Nuclear Research)
Battery Modeling and Management
preprint

Pulsed Discharge of a Lithium-Ion Cell in an Equivalent-Circuit Simulation: Effect of Peak Current and Pulse Period on Usable Capacity

Sahetnur Durdyyev, Umytbek Muradow, Yslam Orazov
preprint en

Abstract

Battery-powered cyber-physical devices often draw current in pulses, for example during radio transmission, and the effect of pulsing on the usable capacity is not obvious. This paper simulates a lithium-ion cell with a Thevenin equivalent circuit (nominal capacity 2.5 Ah, series resistance 60 mΩ, one RC branch with a time constant of 45 s) discharged to a 3.0 V cut-off with five current profiles. A constant 1 A load delivered 2.27 Ah, whereas pulsed loads with the same average current of 1 A (2 A at 50 % duty) delivered 2.17 Ah for a 10 s period and 2.16 Ah for a 120 s period. A 3 A / 33 % duty profile delivered 2.03 Ah. In the model, higher peak currents reach the voltage cut-off earlier because of larger resistive and polarisation voltage drops, leaving more charge unused. The cell parameters and the open-circuit-voltage curve are assumed, not measured. This is a simulation study; all results are outputs of the deposited Python code with assumed parameters. Source code is attached.

Zenodo (CERN European Organization for Nuclear Research)
Oguz Han Engineering and Technology University of Turkmenistan (TM)
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon