Toward Accessible Lung Diagnostics: Design and Development of a Portable Spirometer with IoT-Based Flow Sensor Display

Chronic Obstructive Pulmonary Disease (COPD) is one of the most prevalent respiratory disorders worldwide, yet access to spirometry for early diagnosis remains limited in community and low-resource settings due to the high cost and immobility of conventional devices. This study addresses this gap by designing and developing a portable, IoT-enabled spirometer capable of performing remote lung function examinations, particularly for COPD and asthma patients. The device measures the volume of air entering and leaving the lungs using an AICHI G1/2-inch turbine-type flow sensor, controlled by an ESP32 microcontroller, to obtain FVC (Forced Vital Capacity), FEV1 (Forced Expiratory Volume in 1 second), and the FEV1/FVC ratio. Unlike previous portable spirometer designs, the proposed system transmits measurement data in real time to an Android application developed with MIT App Inventor via Wi-Fi, and enables export of patient records in PDF format. The device accuracy was validated on 60 participants: the FVC error rate ranged from -7.7% to 7.4% (mean absolute error 4.2%), while FEV1 error varied from -59% to 23.4%, with the higher variability attributed to patient effort variability and sensor calibration tolerances. The FEV1/FVC ratio showed generally minimal error. These results demonstrate the feasibility of the proposed system as an accessible and practical tool for lung function assessment and early detection of pulmonary disorders.

Authors

Publication Details

Journal
Journal of Computer Electronic and Telecommunication
Published
2026-11-05
DOI
https://doi.org/10.52435/complete.v7i2.11111
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Toward Accessible Lung Diagnostics: Design and Development of a Portable Spirometer with IoT-Based Flow Sensor Display

Triwiyanto, Reza maulana yanuar, Pasek Wiradarma, Radhitya Raka Nahyatama
Journal of Computer Electronic and Telecommunication
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Toward Accessible Lung Diagnostics: Design and Development of a Portable Spirometer with IoT-Based Flow Sensor Display

Triwiyanto, Reza maulana yanuar, Pasek Wiradarma, Radhitya Raka Nahyatama
article en

Abstract

Chronic Obstructive Pulmonary Disease (COPD) is one of the most prevalent respiratory disorders worldwide, yet access to spirometry for early diagnosis remains limited in community and low-resource settings due to the high cost and immobility of conventional devices. This study addresses this gap by designing and developing a portable, IoT-enabled spirometer capable of performing remote lung function examinations, particularly for COPD and asthma patients. The device measures the volume of air entering and leaving the lungs using an AICHI G1/2-inch turbine-type flow sensor, controlled by an ESP32 microcontroller, to obtain FVC (Forced Vital Capacity), FEV1 (Forced Expiratory Volume in 1 second), and the FEV1/FVC ratio. Unlike previous portable spirometer designs, the proposed system transmits measurement data in real time to an Android application developed with MIT App Inventor via Wi-Fi, and enables export of patient records in PDF format. The device accuracy was validated on 60 participants: the FVC error rate ranged from -7.7% to 7.4% (mean absolute error 4.2%), while FEV1 error varied from -59% to 23.4%, with the higher variability attributed to patient effort variability and sensor calibration tolerances. The FEV1/FVC ratio showed generally minimal error. These results demonstrate the feasibility of the proposed system as an accessible and practical tool for lung function assessment and early detection of pulmonary disorders.

Journal of Computer Electronic and TelecommunicationVol. 7(2)
Openalex Percentile: Top 13%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Toward Accessible Lung Diagnostics: Design and Development of a Portable Spirometer with IoT-Based Flow Sensor Display — Triwiyanto, Reza maulana yanuar, et al. · Journal of Computer Electronic and Telecommunication (2026) | TGRS Research Map | TGRS