Optimal energy storage configuration for multi-energy microgrids based on hybrid multi-stage robust optimization

The source-load uncertainty of a multi-energy microgrid shows markedly different fluctuation characteristics across operating scenarios, which makes an energy storage configuration that balances economy and reliability difficult to obtain. This study proposes an optimal energy storage configuration model for multi-energy microgrids based on hybrid multi-stage robust optimization. An electricity–heat–hydrogen multi-energy microgrid model is first established, and its objective minimizes the sum of the annualized storage investment cost and operation cost. A comprehensive-norm ambiguity set constructed from a 1- and an ∞ -norm constraint then characterizes the uncertainty of the scenario probability distribution, a box uncertainty set with an uncertainty budget characterizes the source-load fluctuation within each scenario, and a min–max–max–min hybrid multi-stage stochastic-robust storage capacity model that accounts for the worst-case scenario probability is formulated. Finally, the column-and-constraint generation (C&CG) algorithm decomposes the model into a master problem and two-level subproblems that are solved iteratively, and the intra-scenario max-min bilevel problem is transformed into an equivalent single-level problem through Karush–Kuhn–Tucker (KKT) conditions. Case studies show that the proposed method hedges against both the source-load output uncertainty and the scenario probability uncertainty, and the configured storage reduces the out-of-sample expected total cost of the microgrid by 6.7% and the worst-case daily cost by 11.3%, and it eliminates the 85.6 kWh daily average loss of load of the storage-free scheme. The conservative nature of the proposed method is tuned flexibly through the uncertainty budget and the confidence level of the comprehensive norm, and a sound balance between economy and robustness is reached.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2026-11-05
DOI
https://doi.org/10.3389/fenrg.2026.1946552
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimal energy storage configuration for multi-energy microgrids based on hybrid multi-stage robust optimization

Xiangyang Su, Xuebo Qiao, Minjia Zheng, Kaiqing Liang et al.
Frontiers in Energy Research
Integrated Energy Systems Optimization
article

Optimal energy storage configuration for multi-energy microgrids based on hybrid multi-stage robust optimization

Xiangyang Su, Xuebo Qiao, Minjia Zheng, Kaiqing Liang, Xinyi Huang, Shucan Zhou, Hao Yu
article en

Abstract

The source-load uncertainty of a multi-energy microgrid shows markedly different fluctuation characteristics across operating scenarios, which makes an energy storage configuration that balances economy and reliability difficult to obtain. This study proposes an optimal energy storage configuration model for multi-energy microgrids based on hybrid multi-stage robust optimization. An electricity–heat–hydrogen multi-energy microgrid model is first established, and its objective minimizes the sum of the annualized storage investment cost and operation cost. A comprehensive-norm ambiguity set constructed from a 1- and an ∞ -norm constraint then characterizes the uncertainty of the scenario probability distribution, a box uncertainty set with an uncertainty budget characterizes the source-load fluctuation within each scenario, and a min–max–max–min hybrid multi-stage stochastic-robust storage capacity model that accounts for the worst-case scenario probability is formulated. Finally, the column-and-constraint generation (C&CG) algorithm decomposes the model into a master problem and two-level subproblems that are solved iteratively, and the intra-scenario max-min bilevel problem is transformed into an equivalent single-level problem through Karush–Kuhn–Tucker (KKT) conditions. Case studies show that the proposed method hedges against both the source-load output uncertainty and the scenario probability uncertainty, and the configured storage reduces the out-of-sample expected total cost of the microgrid by 6.7% and the worst-case daily cost by 11.3%, and it eliminates the 85.6 kWh daily average loss of load of the storage-free scheme. The conservative nature of the proposed method is tuned flexibly through the uncertainty budget and the confidence level of the comprehensive norm, and a sound balance between economy and robustness is reached.

Frontiers in Energy ResearchVol. 14
Guangdong Power Grid Company (China) (CN)
Openalex Percentile: Top 25%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon