Fluorescent glutamate reporter mouse line reveals slow stochastic release from rod photoreceptor cells

The ability to see dim light in darkness requires that second-order rod bipolar cells distinguish small changes in the ongoing release of glutamate-filled vesicles from rods. This task can be facilitated by rapid release, and previous estimates of rod release rates range up to 100 vesicles/s/ribbon. To measure rates and patterns of release, we engineered mice to express a bright fluorescent glutamate reporter (iGluSnFR3.v857.GPI) in rod photoreceptor cells. After validating expression, we measured glutamate release from rods under mesopic and photopic conditions. Under mesopic conditions produced by 900-nm two-photon excitation, light flashes decreased iGluSnFR3 fluorescence consistent with diminished release. Release measured during a chirp light stimulus showed low-pass-frequency characteristics, declining in power from 1 to 10 Hz. To identify single-vesicle events, we loaded iGluSnFR3-expressing rods with dextran-conjugated pHrodo or FM4-64. Brief increases in iGluSnFR3 fluorescence due to vesicle release were accompanied by simultaneous decreases in pHrodo or FM4-64 fluorescence. Tonic release measured from changes in iGluSnFR3 fluorescence occurred stochastically at rates of 20–40 vesicles/s/ribbon under both mesopic and photopic conditions. Capacitance measurements of release from rods voltage-clamped at −40-mV rods suggested a similar rate of 38 vesicles/s/ribbon. The ability of rods to maintain similar release rates over a wide range of background intensities ensures that properties of light adaptation that arise in rods are faithfully transmitted to downstream neurons. This mouse model provides a useful tool for deciphering mechanisms by which light information is transformed at the first synapse in the retina.

Authors

Institutions

Publication Details

Journal
The Journal of General Physiology
Published
2026-11-05
DOI
https://doi.org/10.1085/jgp.202614045
Primary Topic
Neuroscience and Neuropharmacology Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Fluorescent glutamate reporter mouse line reveals slow stochastic release from rod photoreceptor cells

Christopher D. Conrady, Lou E. Townsend, Channabasavaiah B. Gurumurthy, Wallace B. Thoreson et al.
The Journal of General Physiology
Neuroscience and Neuropharmacology Research
article

Fluorescent glutamate reporter mouse line reveals slow stochastic release from rod photoreceptor cells

Christopher D. Conrady, Lou E. Townsend, Channabasavaiah B. Gurumurthy, Wallace B. Thoreson, Kwadwo O. Boateng
article en

Abstract

The ability to see dim light in darkness requires that second-order rod bipolar cells distinguish small changes in the ongoing release of glutamate-filled vesicles from rods. This task can be facilitated by rapid release, and previous estimates of rod release rates range up to 100 vesicles/s/ribbon. To measure rates and patterns of release, we engineered mice to express a bright fluorescent glutamate reporter (iGluSnFR3.v857.GPI) in rod photoreceptor cells. After validating expression, we measured glutamate release from rods under mesopic and photopic conditions. Under mesopic conditions produced by 900-nm two-photon excitation, light flashes decreased iGluSnFR3 fluorescence consistent with diminished release. Release measured during a chirp light stimulus showed low-pass-frequency characteristics, declining in power from 1 to 10 Hz. To identify single-vesicle events, we loaded iGluSnFR3-expressing rods with dextran-conjugated pHrodo or FM4-64. Brief increases in iGluSnFR3 fluorescence due to vesicle release were accompanied by simultaneous decreases in pHrodo or FM4-64 fluorescence. Tonic release measured from changes in iGluSnFR3 fluorescence occurred stochastically at rates of 20–40 vesicles/s/ribbon under both mesopic and photopic conditions. Capacitance measurements of release from rods voltage-clamped at −40-mV rods suggested a similar rate of 38 vesicles/s/ribbon. The ability of rods to maintain similar release rates over a wide range of background intensities ensures that properties of light adaptation that arise in rods are faithfully transmitted to downstream neurons. This mouse model provides a useful tool for deciphering mechanisms by which light information is transformed at the first synapse in the retina.

The Journal of General PhysiologyVol. 159(1)
University of Utah (US), University of Nebraska Medical Center (US)
Openalex Percentile: Top 25%
Neuroscience and Neuropharmacology Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon