Preliminary evidence of systematic longitudinal offsets in couch corrections associated with CT localizer scan-line placement in head-and-neck image-guided radiotherapy: a brief research report

Background Computed tomography (CT) simulation transfers external setup references into treatment planning and image-guided radiotherapy, but the effect of localizer scan-line placement relative to radiopaque markers remains uncertain. Objective This study examined associations between scan-line placement and directional differences in longitudinal couch corrections during head-and-neck image-guided radiotherapy. Methods This single-center study included 104 patients and 3,115 pre-treatment cone-beam CT records. Two operational cohorts used cranial-edge (A) or caudal-edge (B) scan-line alignment. A retrospective routine center-aligned cohort provided a clinical reference (C). The primary endpoint was patient-level treatment-course mean longitudinal couch correction (LNG), retaining treatment-system direction. Absolute LNG, events exceeding 5 mm, mixed-effects models, and an exploratory marker-visibility centroid were analyzed. Results Mean LNG corrections were −0.312, 0.625, and 0.327 mm in groups A, B, and C. The patient-level A-B difference was −0.937 mm [Bonferroni simultaneous 95% confidence interval (CI), −1.865 to −0.009; Holm-adjusted P = 0.0472]. The mixed-effects estimate was −0.930 mm (Bonferroni simultaneous 95% CI, −1.887 to 0.027; Holm-adjusted P = 0.0595). No group difference in mean absolute LNG was detected ( P = 0.5068). Each 1-mm increase in the marker-visibility centroid was associated with a 0.519-mm increase in LNG (HC3 95% CI, 0.367 to 0.671). Conclusion The evaluated workflows showed a small directional difference in pre-treatment longitudinal couch corrections, with statistical support varying across analyses. No difference in mean absolute correction was detected. These hypothesis-generating findings require further validation because scanner–operator confounding, unverified geometry, observer bias, and consent-related selection limit causal interpretation.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-05
DOI
https://doi.org/10.3389/fmed.2026.1962673
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Preliminary evidence of systematic longitudinal offsets in couch corrections associated with CT localizer scan-line placement in head-and-neck image-guided radiotherapy: a brief research report

Jin Wang, Qing Xu, Wei Lu, Qianyong Li
Frontiers in Medicine
Advanced Radiotherapy Techniques
article

Preliminary evidence of systematic longitudinal offsets in couch corrections associated with CT localizer scan-line placement in head-and-neck image-guided radiotherapy: a brief research report

Jin Wang, Qing Xu, Wei Lu, Qianyong Li
article en

Abstract

Background Computed tomography (CT) simulation transfers external setup references into treatment planning and image-guided radiotherapy, but the effect of localizer scan-line placement relative to radiopaque markers remains uncertain. Objective This study examined associations between scan-line placement and directional differences in longitudinal couch corrections during head-and-neck image-guided radiotherapy. Methods This single-center study included 104 patients and 3,115 pre-treatment cone-beam CT records. Two operational cohorts used cranial-edge (A) or caudal-edge (B) scan-line alignment. A retrospective routine center-aligned cohort provided a clinical reference (C). The primary endpoint was patient-level treatment-course mean longitudinal couch correction (LNG), retaining treatment-system direction. Absolute LNG, events exceeding 5 mm, mixed-effects models, and an exploratory marker-visibility centroid were analyzed. Results Mean LNG corrections were −0.312, 0.625, and 0.327 mm in groups A, B, and C. The patient-level A-B difference was −0.937 mm [Bonferroni simultaneous 95% confidence interval (CI), −1.865 to −0.009; Holm-adjusted P = 0.0472]. The mixed-effects estimate was −0.930 mm (Bonferroni simultaneous 95% CI, −1.887 to 0.027; Holm-adjusted P = 0.0595). No group difference in mean absolute LNG was detected ( P = 0.5068). Each 1-mm increase in the marker-visibility centroid was associated with a 0.519-mm increase in LNG (HC3 95% CI, 0.367 to 0.671). Conclusion The evaluated workflows showed a small directional difference in pre-treatment longitudinal couch corrections, with statistical support varying across analyses. No difference in mean absolute correction was detected. These hypothesis-generating findings require further validation because scanner–operator confounding, unverified geometry, observer bias, and consent-related selection limit causal interpretation.

Frontiers in MedicineVol. 13
Shanghai Medical College of Fudan University (CN), Fudan University (CN), Fudan University Shanghai Cancer Center (CN), Shanghai Clinical Research Center (CN)
Openalex Percentile: Top 15%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon