A PPG sensor-based multi-feature machine learning approach for wide-range and high-precision SpO 2 measurement

Objective . This study aimed to improve peripheral oxygen saturation ( SpO 2 ) estimation across a wide range for hypoxemic-risk assessment in chronic obstructive pulmonary disease (COPD) using dual-wavelength photoplethysmography (PPG) and machine learning (ML). Approach . A MAX30102-based module acquired synchronized red (660 nm) and near-infrared (880 nm) PPG signals from the right index finger. A CMS50DA oximeter on the right middle finger provided concurrent reference SpO 2 readings for training and evaluation. Smartphone video captured its display for manual label extraction and independent checking. The ratio-of-ratios ( R ) and morphological, temporal, statistical, and derivative features were extracted. Principal component analysis-based feature selection identified a feature subset. ML and PPG-oriented deep-learning models were compared with conventional R -ratio calibration using mean absolute error (MAE), root mean squared error (RMSE), and the coefficient of determination ( R 2 ). Main results . The Extra Trees regressor achieved the lowest RMSE among evaluated models, with an MAE of 0.38 percentage points, an RMSE of 0.90 percentage points, and an R 2 of 0.91. It outperformed conventional R -ratio calibration. In the hypoxemic range ( 70 % ⩽ SpO 2 ⩽ 90 % ), MAE was 0.98 percentage points, RMSE was 2.04 percentage points, and R 2 was 0.66. Significance . Combining dual-wavelength PPG with multi-domain features and ML shows potential for wide-range SpO 2 estimation and hypoxemic-risk assessment in COPD.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2026-11-19
DOI
https://doi.org/10.1088/1361-6579/aebe9b
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A PPG sensor-based multi-feature machine learning approach for wide-range and high-precision SpO 2 measurement

Xuesheng Ma, Zhen Tong MEI, Haiyang Hu, Zhen Chen et al.
3 links
Physiological Measurement
Non-Invasive Vital Sign Monitoring
article

A PPG sensor-based multi-feature machine learning approach for wide-range and high-precision SpO 2 measurement

Xuesheng Ma, Zhen Tong MEI, Haiyang Hu, Zhen Chen, Lian Guo, De He, Yijun Li
article en

Abstract

Objective . This study aimed to improve peripheral oxygen saturation ( SpO 2 ) estimation across a wide range for hypoxemic-risk assessment in chronic obstructive pulmonary disease (COPD) using dual-wavelength photoplethysmography (PPG) and machine learning (ML). Approach . A MAX30102-based module acquired synchronized red (660 nm) and near-infrared (880 nm) PPG signals from the right index finger. A CMS50DA oximeter on the right middle finger provided concurrent reference SpO 2 readings for training and evaluation. Smartphone video captured its display for manual label extraction and independent checking. The ratio-of-ratios ( R ) and morphological, temporal, statistical, and derivative features were extracted. Principal component analysis-based feature selection identified a feature subset. ML and PPG-oriented deep-learning models were compared with conventional R -ratio calibration using mean absolute error (MAE), root mean squared error (RMSE), and the coefficient of determination ( R 2 ). Main results . The Extra Trees regressor achieved the lowest RMSE among evaluated models, with an MAE of 0.38 percentage points, an RMSE of 0.90 percentage points, and an R 2 of 0.91. It outperformed conventional R -ratio calibration. In the hypoxemic range ( 70 % ⩽ SpO 2 ⩽ 90 % ), MAE was 0.98 percentage points, RMSE was 2.04 percentage points, and R 2 was 0.66. Significance . Combining dual-wavelength PPG with multi-domain features and ML shows potential for wide-range SpO 2 estimation and hypoxemic-risk assessment in COPD.

Physiological MeasurementVol. 47(11)
Tongji University (CN), Southwest University (CN), Chongqing Maternal and Child Health Hospital (CN), Zhuhai Fudan Innovation Research Institute (CN), University of the Western Cape (ZA)
National Natural Science Foundation of China
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon