Aging-Improved NH$_3$ Sensing in Polypyrrole Nanotube Chemiresistors

Polypyrrole NH$_3$ chemiresistors in nanotube (NT) and planar film (PF) morphologies are compared on response magnitude, limit of detection (LOD), sensitivity, and response/recovery kinetics, including the performance of the same sensors tracked over 60 days of ambient storage and repeated NH$_{3}$ exposure. In the case of fresh sensors, the time constants for the fast process ($τ_1$) is shorter in the NT than in the PF at every concentration. NT is 38 \% faster on average than PF. The slow process ($τ_2$) overlaps between two morphologies and shows no concentration dependence. The two time constants differentiate the two morphologies through aging: NT $τ_1$ and $τ_2$ decrease substantially and monotonically over 60 days, while the time constants of PF show no consistent trend. All measured sensing parameters, LOD, sensor response and sensitivity improve or at least remain stable with aging in the case of NT, while all parameters degrade in the PF case. These improved sensor performance and aging identify the nanotube morphology as the more robust and manufacturable choice for long-term NH$_3$ sensing applications.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-03
DOI
https://doi.org/10.48550/arxiv.2611.04917
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Aging-Improved NH$_3$ Sensing in Polypyrrole Nanotube Chemiresistors

Benoit Hackens, Antoine Enel, Arya Mohan, Olivia Kamdom
arXiv (Cornell University)
Gas Sensing Nanomaterials and Sensors
preprint

Aging-Improved NH$_3$ Sensing in Polypyrrole Nanotube Chemiresistors

Benoit Hackens, Antoine Enel, Arya Mohan, Olivia Kamdom
preprint en

Abstract

Polypyrrole NH$_3$ chemiresistors in nanotube (NT) and planar film (PF) morphologies are compared on response magnitude, limit of detection (LOD), sensitivity, and response/recovery kinetics, including the performance of the same sensors tracked over 60 days of ambient storage and repeated NH$_{3}$ exposure. In the case of fresh sensors, the time constants for the fast process ($τ_1$) is shorter in the NT than in the PF at every concentration. NT is 38 \% faster on average than PF. The slow process ($τ_2$) overlaps between two morphologies and shows no concentration dependence. The two time constants differentiate the two morphologies through aging: NT $τ_1$ and $τ_2$ decrease substantially and monotonically over 60 days, while the time constants of PF show no consistent trend. All measured sensing parameters, LOD, sensor response and sensitivity improve or at least remain stable with aging in the case of NT, while all parameters degrade in the PF case. These improved sensor performance and aging identify the nanotube morphology as the more robust and manufacturable choice for long-term NH$_3$ sensing applications.

arXiv (Cornell University)
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon