Indoor/indoor, indoor/outdoor ratios of CO and CO 2 and their measured versus simulated concentrations in roadside eateries using coal-cookstoves

Indoor and outdoor concentrations of CO and CO 2 were studied in two types of roadside eateries, e.g., two sides open (semi-open, n = 6) and closed from three sides (semi-closed, n = 2), both using coal-cookstoves. The 1-h time-weighted average (TWA) indoor CO concentrations ranged from 7.08 to 12.08 ppm in semi-open and 15.46 to 20.92 ppm in semi-closed types, respectively, whereas the corresponding 1-h TWA CO 2 concentrations ranged from 546 to 645 ppm in semi-open and 649.9 to 810.4 ppm in semi-closed types. Notably, 1-h TWA indoor CO concentration exceeded the 6 ppm guideline value followed in Japan in all semi-open and semi-closed eateries but never exceeded WHO limit of 30.6 ppm. The indoor/outdoor (I/O) CO ratios ranged from 7 to 30 in semi-closed eateries and 2 to 19 in semi-open ones. On the other hand, I/O ratios of CO 2 was much lower in both types of eateries viz. 1.2–2.78 and 1.14–1.98 for semi closed and semi open ones. Indoor CO and CO 2 levels simulated by Gaussian dispersion algorithm were comparable to their estimated concentrations under ‘2 cookstoves burning 4 kilograms coal per hour’ scenario. High indoor CO and CO 2 levels implied their build-up in eateries and underscored need for suitable interventions.

Authors

Institutions

Publication Details

Journal
Indoor and Built Environment
Published
2026-11-04
DOI
https://doi.org/10.1177/1420326x261494754
Primary Topic
Energy and Environment Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor/indoor, indoor/outdoor ratios of CO and CO 2 and their measured versus simulated concentrations in roadside eateries using coal-cookstoves

Deepanjan Majumdar, Ayanabha Chaudhury
Indoor and Built Environment
Energy and Environment Impacts
article

Indoor/indoor, indoor/outdoor ratios of CO and CO 2 and their measured versus simulated concentrations in roadside eateries using coal-cookstoves

Deepanjan Majumdar, Ayanabha Chaudhury
article en

Abstract

Indoor and outdoor concentrations of CO and CO 2 were studied in two types of roadside eateries, e.g., two sides open (semi-open, n = 6) and closed from three sides (semi-closed, n = 2), both using coal-cookstoves. The 1-h time-weighted average (TWA) indoor CO concentrations ranged from 7.08 to 12.08 ppm in semi-open and 15.46 to 20.92 ppm in semi-closed types, respectively, whereas the corresponding 1-h TWA CO 2 concentrations ranged from 546 to 645 ppm in semi-open and 649.9 to 810.4 ppm in semi-closed types. Notably, 1-h TWA indoor CO concentration exceeded the 6 ppm guideline value followed in Japan in all semi-open and semi-closed eateries but never exceeded WHO limit of 30.6 ppm. The indoor/outdoor (I/O) CO ratios ranged from 7 to 30 in semi-closed eateries and 2 to 19 in semi-open ones. On the other hand, I/O ratios of CO 2 was much lower in both types of eateries viz. 1.2–2.78 and 1.14–1.98 for semi closed and semi open ones. Indoor CO and CO 2 levels simulated by Gaussian dispersion algorithm were comparable to their estimated concentrations under ‘2 cookstoves burning 4 kilograms coal per hour’ scenario. High indoor CO and CO 2 levels implied their build-up in eateries and underscored need for suitable interventions.

Indoor and Built Environment
National Environmental Engineering Research Institute (IN), XIM University (IN)
Openalex Percentile: Top 27%
Energy and Environment Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Indoor/indoor, indoor/outdoor ratios of CO and CO 2 and their measured versus simulated concentrations in roadside eateries using coal-cookstoves — Deepanjan Majumdar, Ayanabha Chaudhury · Indoor and Built Environment (2026) | TGRS Research Map | TGRS