The Unreported Variable:Collector Selectivity in Data Placement Evaluation

A solid-state drive cannot overwrite data in place, so it cleans full blocks by copying out still-valid data, costing speed and lifetime. Interfaces such as NVMe Flexible Data Placement (FDP) let the host label data by expected lifetime so data dying together is stored together, and published schemes report cutting these copies by 20--75%. Those studies rarely state which blocks the drive chooses to clean. Varying only this choice in simulation, we show it decides how much a label is worth: label value peaks when the drive searches moderately for blocks holding little valid data, falls when it always takes the block with the least, and turns negative when it ignores how much valid data blocks hold. This holds in 47 of 48 synthetic configurations, and one real mail-server trace shows the same shape at about half the magnitude. Priced as spare capacity, a two-class label is worth 65% more spare when each scheme runs at its best setting, but becomes a net loss at 20% label error, typical of learned classifiers. Labels stating which data die together keep most of their value at 16 FDP handles and gain as cleaning improves. Evaluations must report the drive's cleaning policy.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-03
DOI
https://doi.org/10.48550/arxiv.2611.04234
Primary Topic
Advanced Data Storage Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

The Unreported Variable:Collector Selectivity in Data Placement Evaluation

Xiaonan Zhao, Nannan Zhao, Zhijie Huang, Taoyu Zhong et al.
arXiv (Cornell University)
Advanced Data Storage Technologies
preprint

The Unreported Variable:Collector Selectivity in Data Placement Evaluation

Xiaonan Zhao, Nannan Zhao, Zhijie Huang, Taoyu Zhong, Jiameng Zhang, Hao Wang, Shujie Han, Bo Wang, Xiao Zhang
preprint en

Abstract

A solid-state drive cannot overwrite data in place, so it cleans full blocks by copying out still-valid data, costing speed and lifetime. Interfaces such as NVMe Flexible Data Placement (FDP) let the host label data by expected lifetime so data dying together is stored together, and published schemes report cutting these copies by 20--75%. Those studies rarely state which blocks the drive chooses to clean. Varying only this choice in simulation, we show it decides how much a label is worth: label value peaks when the drive searches moderately for blocks holding little valid data, falls when it always takes the block with the least, and turns negative when it ignores how much valid data blocks hold. This holds in 47 of 48 synthetic configurations, and one real mail-server trace shows the same shape at about half the magnitude. Priced as spare capacity, a two-class label is worth 65% more spare when each scheme runs at its best setting, but becomes a net loss at 20% label error, typical of learned classifiers. Labels stating which data die together keep most of their value at 16 FDP handles and gain as cleaning improves. Evaluations must report the drive's cleaning policy.

arXiv (Cornell University)
Advanced Data Storage Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon