Approximating the ideal observer via a variational information bottleneck
PurposeThe Bayesian ideal observer (IO) defines an upper bound on task-based observer performance and is widely used as a theoretical benchmark for optimizing medical imaging systems and data-acquisition designs. However, except in special cases, the exact IO test statistic is analytically intractable. Recent deep neural network (DNN)-based approaches show promise for approximating IO performance while providing limited analytical insight and no guarantee that the learned test statistic corresponds to a likelihood ratio. In addition, their empirical performance can degrade in data-limited regimes, motivating methods that incorporate stronger statistical structure and regularization. To address this, we propose a data-driven framework based on the variational information bottleneck (VIB) to approximate the IO test statistic for binary signal-detection tasks.ApproachThe proposed method utilizes the variational bottleneck principle to encode high-dimensional image data into a low-dimensional latent space optimized to preserve task-relevant information while suppressing nuisance variability. An analytically motivated Gaussian IO loss encourages the class-conditional latent distributions to follow multivariate Gaussian models. Under the adopted Gaussian model for the class-conditional latent distributions, a closed-form Gaussian likelihood-ratio statistic can be evaluated. Unlike end-to-end convolutional neural network (CNN)-based IO approximation methods, this formulation yields an explicit likelihood-ratio test statistic and provides greater analytical interpretability.ResultsNumerical studies demonstrate that the proposed VIB-based IO method achieves detection performance comparable to conventional CNN approaches on large datasets, and superior performance in data-limited regimes. Furthermore, the learned bottleneck representations exhibit stability under the domain shifts examined, supporting robust deployment across varying imaging conditions.ConclusionsThe proposed VIB-IO framework provides a theoretically grounded and relatively data-efficient alternative to conventional CNN-based IO approximations while retaining greater analytical transparency through an explicit latent-space Gaussian observer model. By combining the representational capacity of DNNs with an analytically tractable latent-space observer model, the proposed framework provides a principled approach for objective, task-based assessment of medical imaging systems.
Authors
- Chunsu Park (ORCID: https://orcid.org/0000-0002-9640-7619)
- Zexin Ji (ORCID: https://orcid.org/0000-0002-8811-2335)
- Hua Li (ORCID: https://orcid.org/0000-0002-5629-2247)
- Changjie Lu
Institutions
- University of Illinois Urbana-Champaign (US)
- Washington University in St. Louis (US)
Publication Details
- Journal
- Journal of medical imaging
- Published
- 2026-11-04
- DOI
- https://doi.org/10.1117/1.jmi.13.s2.s22405
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00