Comparative Evaluation of Hydrofluoric Acid Etchants on a 3D-Printed Lithium Disilicate-Filled Polymer Resin

Background: This in vitro study compared the effects of four commercial hydrofluoric acid etchants with different nominal concentrations on the surface roughness of a 3D-printed lithium disilicate-filled polymer resin, evaluated after post-polymerization without debinding or sintering. Methods: Seventy-five specimens were randomly assigned to five groups (n = 15): G1, 4.5% hydrofluoric acid (IPS Ceramic Etching Gel, Ivoclar); G2, 4% hydrofluoric acid (Porcelain Etchant, Bisco); G3, 9.5% hydrofluoric acid (Porcelain Etchant, Bisco); G4, 9% hydrofluoric acid (Porcelain Etch, Ultradent); and G5, an unetched control. Etchants were applied for 20 s. Areal surface roughness (Sa) was measured using non-contact optical profilometry. Data were analyzed using Levene’s test, conventional and Welch’s analyses of variance, and Games–Howell pairwise comparisons (α = 0.05). Results: Both analyses of variance identified significant differences among groups (p < 0.001). All pairwise comparisons were statistically significant (p < 0.001). Mean Sa values were 0.1558 ± 0.0159 µm for G5, 0.3159 ± 0.0313 µm for G1, 0.5093 ± 0.0467 µm for G2, 0.7243 ± 0.0409 µm for G3, and 0.9365 ± 0.0408 µm for G4. The 9% Ultradent etchant produced the greatest roughness, approximately six times the control value. Conclusions: All etchants significantly increased surface roughness. However, the ranking did not follow nominal acid concentration, and differences in commercial formulations prevent attribution of the observed effects to concentration alone. These findings characterize surface modification of a 3D-printed lithium disilicate-filled polymer resin and should not be generalized to conventional lithium disilicate ceramics. Further studies are needed to determine whether these topographic changes improve subsequent adhesive bond strength or long-term durability.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-11-04
DOI
https://doi.org/10.3390/polym18212748
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Hydrofluoric Acid Etchants on a 3D-Printed Lithium Disilicate-Filled Polymer Resin

Fabio Luiz Andretti, Carlos Alberto Jurado, Hamad Algamaiah, René García‐Contreras et al.
Polymers
Dental materials and restorations
article

Comparative Evaluation of Hydrofluoric Acid Etchants on a 3D-Printed Lithium Disilicate-Filled Polymer Resin

Fabio Luiz Andretti, Carlos Alberto Jurado, Hamad Algamaiah, René García‐Contreras, Abdulrahman Alshabib, Abdullah Almansour, Silvia Rojas‐Rueda, Jose Vivaldi
article en

Abstract

Background: This in vitro study compared the effects of four commercial hydrofluoric acid etchants with different nominal concentrations on the surface roughness of a 3D-printed lithium disilicate-filled polymer resin, evaluated after post-polymerization without debinding or sintering. Methods: Seventy-five specimens were randomly assigned to five groups (n = 15): G1, 4.5% hydrofluoric acid (IPS Ceramic Etching Gel, Ivoclar); G2, 4% hydrofluoric acid (Porcelain Etchant, Bisco); G3, 9.5% hydrofluoric acid (Porcelain Etchant, Bisco); G4, 9% hydrofluoric acid (Porcelain Etch, Ultradent); and G5, an unetched control. Etchants were applied for 20 s. Areal surface roughness (Sa) was measured using non-contact optical profilometry. Data were analyzed using Levene’s test, conventional and Welch’s analyses of variance, and Games–Howell pairwise comparisons (α = 0.05). Results: Both analyses of variance identified significant differences among groups (p < 0.001). All pairwise comparisons were statistically significant (p < 0.001). Mean Sa values were 0.1558 ± 0.0159 µm for G5, 0.3159 ± 0.0313 µm for G1, 0.5093 ± 0.0467 µm for G2, 0.7243 ± 0.0409 µm for G3, and 0.9365 ± 0.0408 µm for G4. The 9% Ultradent etchant produced the greatest roughness, approximately six times the control value. Conclusions: All etchants significantly increased surface roughness. However, the ranking did not follow nominal acid concentration, and differences in commercial formulations prevent attribution of the observed effects to concentration alone. These findings characterize surface modification of a 3D-printed lithium disilicate-filled polymer resin and should not be generalized to conventional lithium disilicate ceramics. Further studies are needed to determine whether these topographic changes improve subsequent adhesive bond strength or long-term durability.

PolymersVol. 18(21)
Prince Sattam Bin Abdulaziz University (SA), University of Tennessee Health Science Center (US), Ponce Health Sciences University (PR), King Saud University (SA), Universidad Nacional Autónoma de México (MX)
Openalex Percentile: Top 11%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon