The Impact of Varying the Femoral Head Diameter on Stability of Hip Implants

Hip Implant failures have increased the number of revision surgeries in recent years due to the effect of dislocation. Hence, remedying the effect of dislocation in Hip Implants is one of the target focus for Biomechanics research scholars. The research investigates how different femoral head diameters impact on stability in complete hip replacement implants. The research used SolidWorks Premium 2025 to create seven hip implant models with Ti-6Al-4V alloy biomaterials and different femoral head diameters from 28mm to 52mm. The implants underwent finite element analysis through ANSYS 2022 R-2 to determine their deformations. The research findings show that deformations decrease when femoral head diameters increase. The 28mm femoral head diameter produced the highest deformation of 0.025918mm, but the 52mm diameter produced the lowest stress of 0.025009mm. Studies have shown that larger femoral head diameters are associated with reduced risk of revision for dislocation and enhances stability. Hence, the research findings are acceptable and shows how different femoral head diameters affect hip implant stability.

Authors

Institutions

Publication Details

Journal
INTERNATIONAL JOURNAL OF ENGINEERING AND MODERN TECHNOLOGY
Published
2026-11-04
DOI
https://doi.org/10.56201/ijemt.vol.12.no10.2026.pg70.79
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Varying the Femoral Head Diameter on Stability of Hip Implants

Komonibo Ernest Bolouebi
INTERNATIONAL JOURNAL OF ENGINEERING AND MODERN TECHNOLOGY
Orthopaedic implants and arthroplasty
article

The Impact of Varying the Femoral Head Diameter on Stability of Hip Implants

Komonibo Ernest Bolouebi
article en

Abstract

Hip Implant failures have increased the number of revision surgeries in recent years due to the effect of dislocation. Hence, remedying the effect of dislocation in Hip Implants is one of the target focus for Biomechanics research scholars. The research investigates how different femoral head diameters impact on stability in complete hip replacement implants. The research used SolidWorks Premium 2025 to create seven hip implant models with Ti-6Al-4V alloy biomaterials and different femoral head diameters from 28mm to 52mm. The implants underwent finite element analysis through ANSYS 2022 R-2 to determine their deformations. The research findings show that deformations decrease when femoral head diameters increase. The 28mm femoral head diameter produced the highest deformation of 0.025918mm, but the 52mm diameter produced the lowest stress of 0.025009mm. Studies have shown that larger femoral head diameters are associated with reduced risk of revision for dislocation and enhances stability. Hence, the research findings are acceptable and shows how different femoral head diameters affect hip implant stability.

INTERNATIONAL JOURNAL OF ENGINEERING AND MODERN TECHNOLOGY
University of Africa Toru-Orua (NG)
Openalex Percentile: Top 11%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon