Environmental circulation of airborne SARS-CoV-2 particles in intensive care rooms

Abstract Background: Airborne transmission is a major concern in intensive care units (ICUs). This study aimed to identify the determinants of airborne and surface contamination in ICU rooms occupied by patients with COVID-19 associated respiratory failure. Methods: Observational study in a tertiary care hospital comprising six ICUs with diverse architectural layouts and HVAC systems. We modeled the dispersion of respiratory particles in five rooms using computational fluid dynamics (CFD). Air and surface samples were collected at predefined locations in 19 rooms occupied by 28 patients testing positive for SARS-CoV-2. Risk factors associated with environmental contamination were identified using classification tree analysis. Results: Measured HVAC airflow rates were substantially lower than programmed values in three ICUs. CFD simulations suggested that exhaled particles initially rose above the patient, accumulated beneath the ceiling, and subsequently dispersed in the room. SARS-CoV-2 was detected in 14/64 (22%) air samples and 60/134 (45%) surface samples. The most important determinants of environmental contamination were patient viral load, room characteristics, and mode of respiratory support. Environmental contamination was more frequent in rooms with low airflow rates and extraction vents located outside the room. Conclusion: In our ICUs, the main factors associated with environmental detection of SARS-CoV-2 particles were patient airway viral load, the flow rate and location of the exhaust ventilation system, and the use of mechanical ventilation. These results could help guide the renovation or construction of intensive care rooms.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-04
DOI
https://doi.org/10.21203/rs.3.rs-11306071/v1
Primary Topic
Infection Control and Ventilation
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Environmental circulation of airborne SARS-CoV-2 particles in intensive care rooms

Cécile Meex, Éric Haubruge, Pauline Pitti, Charlotte De Harenne et al.
Research Square
Infection Control and Ventilation
preprint

Environmental circulation of airborne SARS-CoV-2 particles in intensive care rooms

Cécile Meex, Éric Haubruge, Pauline Pitti, Charlotte De Harenne, Maxime Lisson, Marie‐Pierre Hayette, Claude Saegerman, Pedro Javier Obando Vega, Alessandro Gambale, Axelle Bertrand, Gabriele Mosca, Benoît Misset, Mouhssine Lamtiri, Sophie Kesseler
preprint en

Abstract

Abstract Background: Airborne transmission is a major concern in intensive care units (ICUs). This study aimed to identify the determinants of airborne and surface contamination in ICU rooms occupied by patients with COVID-19 associated respiratory failure. Methods: Observational study in a tertiary care hospital comprising six ICUs with diverse architectural layouts and HVAC systems. We modeled the dispersion of respiratory particles in five rooms using computational fluid dynamics (CFD). Air and surface samples were collected at predefined locations in 19 rooms occupied by 28 patients testing positive for SARS-CoV-2. Risk factors associated with environmental contamination were identified using classification tree analysis. Results: Measured HVAC airflow rates were substantially lower than programmed values in three ICUs. CFD simulations suggested that exhaled particles initially rose above the patient, accumulated beneath the ceiling, and subsequently dispersed in the room. SARS-CoV-2 was detected in 14/64 (22%) air samples and 60/134 (45%) surface samples. The most important determinants of environmental contamination were patient viral load, room characteristics, and mode of respiratory support. Environmental contamination was more frequent in rooms with low airflow rates and extraction vents located outside the room. Conclusion: In our ICUs, the main factors associated with environmental detection of SARS-CoV-2 particles were patient airway viral load, the flow rate and location of the exhaust ventilation system, and the use of mechanical ventilation. These results could help guide the renovation or construction of intensive care rooms.

Research Square
University of Liège (BE), Centre Hospitalier Universitaire de Liège (BE)
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon