Comparative detection of red cell alloantibodies by solid‐phase red cell adherence and column agglutination technology in routine pre‐transfusion testing

Abstract Background and Objectives Detection of clinically significant alloantibodies (CSAs), particularly weak or weakly reactive antibodies, remains challenging with conventional agglutination methods and may contribute to delayed haemolytic transfusion reactions (DHTRs). Antibodies known to be associated with DHTRs or reduced red cell survival were classified as CSAs. We aimed to compare solid‐phase red cell adherence (SPRCA) and column agglutination technology (CAT) for antibody screening and identification. Materials and Methods In this retrospective study, 33,340 antibody screens (September 2023–March 2025) were evaluated by SPRCA and CAT. Reactive or inconclusive samples underwent antibody identification by both methods with enzyme‐phase testing. Agreement was assessed using positive (PPA) and negative percent agreement (NPA). Results Of the 33,340 samples, 547 (1.6%) were screen‐positive or inconclusive. Screening agreement was high (PPA 98.5%, NPA 99.8%). Of the 546 evaluable samples, 464 (84.8%) were reactive by both methods. At least one CSA was identified in 405/546 samples (74.2%). SPRCA detected CSAs in 398/405 samples (98.3%) compared to 331/405 (81.7%) by CAT, and identified 490 antibodies versus 401 by CAT (450 after enzyme enhancement). CAT did not detect 102 CSAs in 86 samples detected by SPRCA. SPRCA did not detect 13 CSAs in nine samples detected by CAT. Most additional antibodies detected by SPRCA belonged to Rh, Kell, Kidd and Duffy systems, with largest relative gains observed for Duffy (60%), Kidd (45%) and Kell (44%) antibodies. Conclusion SPRCA demonstrated greater analytical sensitivity than CAT for detecting weakly reactive CSAs, particularly in the Rh, Kidd and Kell systems. These findings support the potential utility of SPRCA as a complementary method in selected clinical settings.

Authors

Institutions

Publication Details

Journal
Vox Sanguinis
Published
2026-11-04
DOI
https://doi.org/10.1111/vox.70409
Primary Topic
Blood groups and transfusion
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative detection of red cell alloantibodies by solid‐phase red cell adherence and column agglutination technology in routine pre‐transfusion testing

Amena Ebadur Rahman, Rasika Setia, Mitu Dogra, Deepa Tiwari et al.
Vox Sanguinis
Blood groups and transfusion
article

Comparative detection of red cell alloantibodies by solid‐phase red cell adherence and column agglutination technology in routine pre‐transfusion testing

Amena Ebadur Rahman, Rasika Setia, Mitu Dogra, Deepa Tiwari, Vadad Khaleeq
article en

Abstract

Abstract Background and Objectives Detection of clinically significant alloantibodies (CSAs), particularly weak or weakly reactive antibodies, remains challenging with conventional agglutination methods and may contribute to delayed haemolytic transfusion reactions (DHTRs). Antibodies known to be associated with DHTRs or reduced red cell survival were classified as CSAs. We aimed to compare solid‐phase red cell adherence (SPRCA) and column agglutination technology (CAT) for antibody screening and identification. Materials and Methods In this retrospective study, 33,340 antibody screens (September 2023–March 2025) were evaluated by SPRCA and CAT. Reactive or inconclusive samples underwent antibody identification by both methods with enzyme‐phase testing. Agreement was assessed using positive (PPA) and negative percent agreement (NPA). Results Of the 33,340 samples, 547 (1.6%) were screen‐positive or inconclusive. Screening agreement was high (PPA 98.5%, NPA 99.8%). Of the 546 evaluable samples, 464 (84.8%) were reactive by both methods. At least one CSA was identified in 405/546 samples (74.2%). SPRCA detected CSAs in 398/405 samples (98.3%) compared to 331/405 (81.7%) by CAT, and identified 490 antibodies versus 401 by CAT (450 after enzyme enhancement). CAT did not detect 102 CSAs in 86 samples detected by SPRCA. SPRCA did not detect 13 CSAs in nine samples detected by CAT. Most additional antibodies detected by SPRCA belonged to Rh, Kell, Kidd and Duffy systems, with largest relative gains observed for Duffy (60%), Kidd (45%) and Kell (44%) antibodies. Conclusion SPRCA demonstrated greater analytical sensitivity than CAT for detecting weakly reactive CSAs, particularly in the Rh, Kidd and Kell systems. These findings support the potential utility of SPRCA as a complementary method in selected clinical settings.

Vox Sanguinis
Max Super Speciality Hospital (IN), Shree Guru Gobind Singh Tricentenary University (IN), BLK Super Speciality Hospital (IN)
Openalex Percentile: Top 13%
Blood groups and transfusion
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon