Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study

Abstract Purpose This study aimed to evaluate the accuracy of a root‐shaped extraction socket–supported guide (ESSG) for anterior single‐tooth immediate implant placement. Materials and Methods After the central incisors were digitally removed from cone beam computed tomography (CBCT) images obtained from patients, 3D‐printed models were created to simulate labial (Type I), central (Type II), and palatal root‐position deviation (Type III) in the sagittal plane. Resin models of each type were divided into high‐elastic‐modulus (HE) and normal‐elastic‐modulus (NE) subgroups. In total, 120 implants were immediately placed using ESSGs (test group) or tooth‐supported surgical guides (TSSGs; control group). The angular and positional deviations were assessed by comparing post‐placement CBCT scans with the corresponding virtual implant plans. Results In Type I and III resin models, angular deviations were significantly smaller in the test group ( p < 0.05) than in the control group, with values of 1.34° ± 0.75° versus 4.28° ± 0.71° (Type I, HE), 0.83° ± 0.76° versus 2.74° ± 1.05° (Type I, NE), 1.18° ± 0.82° versus 3.57° ± 1.40° (Type III, HE), and 1.17° ± 0.79° versus 3.41° ± 1.16° (Type III, NE), respectively. Positional deviations in most Type I and III resin models were likewise significantly lower in the test group than in the control group. Notably, ESSGs maintained high accuracy in HE resin models of Types I and III. Conclusions ESSGs demonstrated greater precision than TSSGs in resin models simulating labial and palatal deviations of socket morphology. Nevertheless, clinical studies are still needed to evaluate their applicability in patients.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-11-04
DOI
https://doi.org/10.1111/jopr.70271
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study

Jianye Song, Wenhao Yang, Zuge Yang, Kun Wang et al.
Journal of Prosthodontics
Dental Implant Techniques and Outcomes
article

Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study

Jianye Song, Wenhao Yang, Zuge Yang, Kun Wang, Weiwei Guo, Zhonghua Cao, Zhenxin Huang, Fangke Jiang
article en

Abstract

Abstract Purpose This study aimed to evaluate the accuracy of a root‐shaped extraction socket–supported guide (ESSG) for anterior single‐tooth immediate implant placement. Materials and Methods After the central incisors were digitally removed from cone beam computed tomography (CBCT) images obtained from patients, 3D‐printed models were created to simulate labial (Type I), central (Type II), and palatal root‐position deviation (Type III) in the sagittal plane. Resin models of each type were divided into high‐elastic‐modulus (HE) and normal‐elastic‐modulus (NE) subgroups. In total, 120 implants were immediately placed using ESSGs (test group) or tooth‐supported surgical guides (TSSGs; control group). The angular and positional deviations were assessed by comparing post‐placement CBCT scans with the corresponding virtual implant plans. Results In Type I and III resin models, angular deviations were significantly smaller in the test group ( p < 0.05) than in the control group, with values of 1.34° ± 0.75° versus 4.28° ± 0.71° (Type I, HE), 0.83° ± 0.76° versus 2.74° ± 1.05° (Type I, NE), 1.18° ± 0.82° versus 3.57° ± 1.40° (Type III, HE), and 1.17° ± 0.79° versus 3.41° ± 1.16° (Type III, NE), respectively. Positional deviations in most Type I and III resin models were likewise significantly lower in the test group than in the control group. Notably, ESSGs maintained high accuracy in HE resin models of Types I and III. Conclusions ESSGs demonstrated greater precision than TSSGs in resin models simulating labial and palatal deviations of socket morphology. Nevertheless, clinical studies are still needed to evaluate their applicability in patients.

Journal of Prosthodontics
Army Medical University (CN), Xinqiao Hospital (CN), Air Force Medical University (CN)
Openalex Percentile: Top 12%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Accuracy of an innovative extraction socket–supported guide for immediate anterior implantation: An in vitro study — Jianye Song, Wenhao Yang, et al. · Journal of Prosthodontics (2026) | TGRS Research Map | TGRS