Decomposing Marker-to-Keypoint Discrepancy in Stereo Markerless Motion Capture: A Comparison of Three Pose-Estimation Architectures Against OptiTrack

When a markerless system is validated against marker-based motion capture, the result is usually a single number: the average distance between the two systems at a given joint. That number is read as the accuracy of the pose estimator, but it also contains everything else in the measurement chain—where the markers were placed, how well the systems were synchronised, and how good the calibration was. We asked whether differences and rankings between pose estimators remain interpretable once this uncertainty is accounted for. In a single-participant methodological case study, three checkpoints from MMPose, an open-source pose-estimation toolbox (ViTPose, RTMPose-m, HRNet-w32), were compared against an OptiTrack reference using a calibrated stereo pair of industrial cameras in recordings of the elbow and wrist. The distance between the marker-pair midpoint and the triangulated keypoint had a median of 23.9 to 47.1 mm. Calibration, reconstruction scale, temporal offset and median sampling error gave the group medians a combined standard uncertainty of 4.5–14.9 mm (a lower bound, excluding marker placement). No difference between the three checkpoints was resolvable above the uncertainty of the measurement chain, and the leading checkpoint changed when the calibration was resampled. As supporting mechanisms, marker placement produced an offset comparable to the measured distance, whereas the temporal offset barely changed it. These numbers are specific to this participant and protocol; the transferable contribution is the validation and uncertainty-analysis framework.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-04
DOI
https://doi.org/10.3390/app162110922
Primary Topic
Human Pose and Action Recognition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Decomposing Marker-to-Keypoint Discrepancy in Stereo Markerless Motion Capture: A Comparison of Three Pose-Estimation Architectures Against OptiTrack

Adam Chromý, Oto Haffner, Danica Rosinová, Ján Cigánek et al.
Applied Sciences
Human Pose and Action Recognition
article

Decomposing Marker-to-Keypoint Discrepancy in Stereo Markerless Motion Capture: A Comparison of Three Pose-Estimation Architectures Against OptiTrack

Adam Chromý, Oto Haffner, Danica Rosinová, Ján Cigánek, Marián Choma
article en

Abstract

When a markerless system is validated against marker-based motion capture, the result is usually a single number: the average distance between the two systems at a given joint. That number is read as the accuracy of the pose estimator, but it also contains everything else in the measurement chain—where the markers were placed, how well the systems were synchronised, and how good the calibration was. We asked whether differences and rankings between pose estimators remain interpretable once this uncertainty is accounted for. In a single-participant methodological case study, three checkpoints from MMPose, an open-source pose-estimation toolbox (ViTPose, RTMPose-m, HRNet-w32), were compared against an OptiTrack reference using a calibrated stereo pair of industrial cameras in recordings of the elbow and wrist. The distance between the marker-pair midpoint and the triangulated keypoint had a median of 23.9 to 47.1 mm. Calibration, reconstruction scale, temporal offset and median sampling error gave the group medians a combined standard uncertainty of 4.5–14.9 mm (a lower bound, excluding marker placement). No difference between the three checkpoints was resolvable above the uncertainty of the measurement chain, and the leading checkpoint changed when the calibration was resampled. As supporting mechanisms, marker placement produced an offset comparable to the measured distance, whereas the temporal offset barely changed it. These numbers are specific to this participant and protocol; the transferable contribution is the validation and uncertainty-analysis framework.

Applied SciencesVol. 16(21)
Slovak University of Technology in Bratislava (SK), Brno University of Technology (CZ)
Openalex Percentile: Top 19%
Human Pose and Action Recognition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon