Photon-Counting CT Versus Energy-Integrating CT Angiography for Craniocervical Fibromuscular Dysplasia: A Preliminary Retrospective Paired Analysis

BACKGROUND: Assessing craniocervical fibromuscular dysplasia (cc-FMD) can be challenging using cross-sectional imaging. We hypothesize that photon-counting detector CT (PCD-CT), owing to its superior spatial resolution over conventional energy-integrating detector CT (EID-CT), may better help appreciate changes in cc-FMD. MATERIALS AND METHODS: In this retrospective cohort, 24 patients with radiologically reported cc-FMD (mean age: 54 y; 75% women) underwent both PCD-CT and EID-CT within 180 days (median: 52 d). Bilateral internal carotid (ICA) and vertebral artery (VA) segments without dissection/occlusion were graded on a 3-point scale (absent/likely present/present). Intermodality agreement was evaluated with weighted Cohen κ, and radiation dose metrics (CTDIvol) were compared using the paired Wilcoxon signed-rank tests. RESULTS: Eighty-seven paired segments were analyzed. PCD-CT detected FMD in 48 segments (55.1%) versus 30 (34.5%) on EID-CT. The mean reader confidence scores were consistently higher with PCD-CT compared with EID-CT, for both ICAs (2.16±0.95 vs. 1.93±0.99) and VAs (1.86±0.95 vs. 1.36±0.75). Intermodality agreement was almost perfect for ICAs (κ=0.807) and substantial for VAs (κ=0.662). Under our institutional protocols, median CTDIvol was lower with PCD-CT (16.6 mGy) than EID-CT (21.5 mGy; P=0.0112). CONCLUSION: PCD-CT demonstrated more frequent reader categorization of cc-FMD features than EID-CT, particularly in the VAs, and had a lower median CTDIvol under our institutional protocols. These preliminary findings suggest improved cc-FMD detection with PCD-CT as compared with EID-CT and require prospective, reference-standard validation to establish accuracy and clinical impact.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-11-04
DOI
https://doi.org/10.1097/rct.0000000000001939
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-Counting CT Versus Energy-Integrating CT Angiography for Craniocervical Fibromuscular Dysplasia: A Preliminary Retrospective Paired Analysis

John Charles Benson, Pranjal Rai, Neetu Soni, Shravani Kharat et al.
Journal of Computer Assisted Tomography
Advanced X-ray and CT Imaging
article

Photon-Counting CT Versus Energy-Integrating CT Angiography for Craniocervical Fibromuscular Dysplasia: A Preliminary Retrospective Paired Analysis

John Charles Benson, Pranjal Rai, Neetu Soni, Shravani Kharat, Amit Agarwal, Felix E. Diehn, Girish Bathla, Ahmed O El Sadaney, Lifeng Yu, Vincent E. Y. Chan, Victoria M. Silvera
article en

Abstract

BACKGROUND: Assessing craniocervical fibromuscular dysplasia (cc-FMD) can be challenging using cross-sectional imaging. We hypothesize that photon-counting detector CT (PCD-CT), owing to its superior spatial resolution over conventional energy-integrating detector CT (EID-CT), may better help appreciate changes in cc-FMD. MATERIALS AND METHODS: In this retrospective cohort, 24 patients with radiologically reported cc-FMD (mean age: 54 y; 75% women) underwent both PCD-CT and EID-CT within 180 days (median: 52 d). Bilateral internal carotid (ICA) and vertebral artery (VA) segments without dissection/occlusion were graded on a 3-point scale (absent/likely present/present). Intermodality agreement was evaluated with weighted Cohen κ, and radiation dose metrics (CTDIvol) were compared using the paired Wilcoxon signed-rank tests. RESULTS: Eighty-seven paired segments were analyzed. PCD-CT detected FMD in 48 segments (55.1%) versus 30 (34.5%) on EID-CT. The mean reader confidence scores were consistently higher with PCD-CT compared with EID-CT, for both ICAs (2.16±0.95 vs. 1.93±0.99) and VAs (1.86±0.95 vs. 1.36±0.75). Intermodality agreement was almost perfect for ICAs (κ=0.807) and substantial for VAs (κ=0.662). Under our institutional protocols, median CTDIvol was lower with PCD-CT (16.6 mGy) than EID-CT (21.5 mGy; P=0.0112). CONCLUSION: PCD-CT demonstrated more frequent reader categorization of cc-FMD features than EID-CT, particularly in the VAs, and had a lower median CTDIvol under our institutional protocols. These preliminary findings suggest improved cc-FMD detection with PCD-CT as compared with EID-CT and require prospective, reference-standard validation to establish accuracy and clinical impact.

Journal of Computer Assisted Tomography
Mayo Clinic (US), The University of Texas MD Anderson Cancer Center (US), Mayo Clinic in Florida (US)
Openalex Percentile: Top 26%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon