AI-based chest circumference measurement from a photograph in children: a YOLO11-pose keypoint detection study

Accurate subxiphoid chest circumference assessment is required for the clinical evaluation and treatment planning of children with microtia. Conventional tape measurement requires an in-person visit and is prone to measurement-site error when performed by untrained caregivers. We developed a non-contact AI approach that employs a YOLO11-pose model to detect bilateral chest keypoints and a Ramanujan ellipse model to estimate subxiphoid chest circumference from a single frontal photograph, with the lateral view used solely for verification of chest depth. A single-center observational diagnostic-accuracy study of 500 children with microtia (250 boys, 250 girls) was conducted. Reference subxiphoid chest circumference was measured by trained personnel; AI prediction used YOLO11-pose keypoint detection with Ramanujan ellipse geometric modeling (chest depth = width × 0.75). The cohort was split into a development set (400 cases) and a locked test set (100 cases). Performance was assessed by mean absolute error (MAE), root mean squared error (RMSE), Pearson correlation, and Bland–Altman agreement, with bootstrap 95% confidence intervals. In the locked test set (n = 100), MAE was 0.938 cm (95% CI 0.799–1.089), RMSE was 1.193 cm (95% CI 1.029–1.364), median absolute error was 0.80 cm, and mean bias was − 0.127 cm (95% CI − 0.359 to 0.108). Predictions were within 2, 3, and 5 cm of the reference in 93.0%, 99.0%, and 100% of cases. Pearson correlation was 0.935 (R 2 = 0.856). MAE was 0.897 cm in the normal-weight subgroup and 1.025 cm in the overweight/obesity subgroup. At a 60-cm threshold, sensitivity was 87.3%, specificity was 100.0%, and overall accuracy was 90.0%. A YOLO11-pose and Ramanujan ellipse pipeline can achieve high accuracy for non-contact subxiphoid chest circumference estimation in children with microtia under standardized imaging conditions, and mitigates measurement-site error by non-medical users through automated landmark detection. Because all images were acquired under controlled conditions, the reported performance may not directly reflect real-world in-home use. Performance was slightly lower in the overweight/obesity subgroup, warranting further validation in larger cohorts.

Authors

Institutions

Publication Details

Journal
European journal of medical research
Published
2026-11-04
DOI
https://doi.org/10.1186/s40001-026-05439-w
Primary Topic
Advanced Neural Network Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-based chest circumference measurement from a photograph in children: a YOLO11-pose keypoint detection study

Zhicheng Xu, Feng Xu, Datao Li, Ruhong Zhang et al.
European journal of medical research
Advanced Neural Network Applications
article

AI-based chest circumference measurement from a photograph in children: a YOLO11-pose keypoint detection study

Zhicheng Xu, Feng Xu, Datao Li, Ruhong Zhang, Qun Zhang, Xinyu Li, Yiyuan Li
article en

Abstract

Accurate subxiphoid chest circumference assessment is required for the clinical evaluation and treatment planning of children with microtia. Conventional tape measurement requires an in-person visit and is prone to measurement-site error when performed by untrained caregivers. We developed a non-contact AI approach that employs a YOLO11-pose model to detect bilateral chest keypoints and a Ramanujan ellipse model to estimate subxiphoid chest circumference from a single frontal photograph, with the lateral view used solely for verification of chest depth. A single-center observational diagnostic-accuracy study of 500 children with microtia (250 boys, 250 girls) was conducted. Reference subxiphoid chest circumference was measured by trained personnel; AI prediction used YOLO11-pose keypoint detection with Ramanujan ellipse geometric modeling (chest depth = width × 0.75). The cohort was split into a development set (400 cases) and a locked test set (100 cases). Performance was assessed by mean absolute error (MAE), root mean squared error (RMSE), Pearson correlation, and Bland–Altman agreement, with bootstrap 95% confidence intervals. In the locked test set (n = 100), MAE was 0.938 cm (95% CI 0.799–1.089), RMSE was 1.193 cm (95% CI 1.029–1.364), median absolute error was 0.80 cm, and mean bias was − 0.127 cm (95% CI − 0.359 to 0.108). Predictions were within 2, 3, and 5 cm of the reference in 93.0%, 99.0%, and 100% of cases. Pearson correlation was 0.935 (R 2 = 0.856). MAE was 0.897 cm in the normal-weight subgroup and 1.025 cm in the overweight/obesity subgroup. At a 60-cm threshold, sensitivity was 87.3%, specificity was 100.0%, and overall accuracy was 90.0%. A YOLO11-pose and Ramanujan ellipse pipeline can achieve high accuracy for non-contact subxiphoid chest circumference estimation in children with microtia under standardized imaging conditions, and mitigates measurement-site error by non-medical users through automated landmark detection. Because all images were acquired under controlled conditions, the reported performance may not directly reflect real-world in-home use. Performance was slightly lower in the overweight/obesity subgroup, warranting further validation in larger cohorts.

European journal of medical research
Shanghai Jiao Tong University (CN), The Fourth People's Hospital (CN), Shanghai Ninth People's Hospital (CN)
Openalex Percentile: Top 19%
Advanced Neural Network Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon