Synergistic Optimization of Daylighting and Carbon Emissions in University Teaching Buildings from the Perspective of Spatial Heterogeneity

In the context of global carbon reduction, university teaching buildings, as typical densely populated public spaces, face the dual challenges of high operational carbon emissions and strict daylighting demands. This study therefore focuses on jointly improving daylighting performance and reducing operational carbon emissions. However, current optimization practices are largely constrained by a “homogeneous” design paradigm applied to spatial layouts and building envelopes, which fails to fully exploit the passive energy-saving potential of buildings. To address this limitation, this study proposes a daylighting-carbon emission synergistic optimization framework integrating parametric modeling, Non-dominated Sorting Genetic Algorithm II (NSGA-II) multi-objective optimization, Stacking ensemble prediction models, and Shapley Additive Explanations (SHAP) analysis. The results indicate that: (1) compared to the homogeneous baseline model, the comprehensive Pareto optimal solution reduces the operational carbon emission intensity (CEI) by 12.5%, while simultaneously increasing spatial daylight autonomy (sDA) and useful daylight illuminance (UDI) by 14.1% and 18.9%, respectively; (2) the Pareto optimal solutions exhibit distinct heterogeneous distribution characteristics in spatial morphology and facade configuration. Specifically, the floor plan adopts an asymmetrical layout characterized by “deep south (9.0–9.5 m) and shallow north (6.5–7.0 m)” zones, while the facade window-to-wall ratio (WWR) displays a vertical gradient of “larger upper and smaller lower” openings (with a high-to-low zone WWR ratio of 1.07–1.25); (3) the two developed Stacking prediction models achieve R2 values greater than 0.90, substantially reducing the computational cost of dynamic simulations while ensuring high predictive accuracy; (4) SHAP analysis quantifies the contributions of 24 design parameters and 12 spatial heterogeneity indicators (HIs) to model predictions of daylighting and carbon performance. In conclusion, this study proposes heterogeneous design strategies, providing a scientific reference for the synergistic optimization of daylighting and carbon emissions in teaching buildings located in cold climates.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-04
DOI
https://doi.org/10.3390/buildings16214422
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergistic Optimization of Daylighting and Carbon Emissions in University Teaching Buildings from the Perspective of Spatial Heterogeneity

Jieli Sui, Yang Ming, Shuyuan Mai
Buildings
Building Energy and Comfort Optimization
article

Synergistic Optimization of Daylighting and Carbon Emissions in University Teaching Buildings from the Perspective of Spatial Heterogeneity

Jieli Sui, Yang Ming, Shuyuan Mai
article en

Abstract

In the context of global carbon reduction, university teaching buildings, as typical densely populated public spaces, face the dual challenges of high operational carbon emissions and strict daylighting demands. This study therefore focuses on jointly improving daylighting performance and reducing operational carbon emissions. However, current optimization practices are largely constrained by a “homogeneous” design paradigm applied to spatial layouts and building envelopes, which fails to fully exploit the passive energy-saving potential of buildings. To address this limitation, this study proposes a daylighting-carbon emission synergistic optimization framework integrating parametric modeling, Non-dominated Sorting Genetic Algorithm II (NSGA-II) multi-objective optimization, Stacking ensemble prediction models, and Shapley Additive Explanations (SHAP) analysis. The results indicate that: (1) compared to the homogeneous baseline model, the comprehensive Pareto optimal solution reduces the operational carbon emission intensity (CEI) by 12.5%, while simultaneously increasing spatial daylight autonomy (sDA) and useful daylight illuminance (UDI) by 14.1% and 18.9%, respectively; (2) the Pareto optimal solutions exhibit distinct heterogeneous distribution characteristics in spatial morphology and facade configuration. Specifically, the floor plan adopts an asymmetrical layout characterized by “deep south (9.0–9.5 m) and shallow north (6.5–7.0 m)” zones, while the facade window-to-wall ratio (WWR) displays a vertical gradient of “larger upper and smaller lower” openings (with a high-to-low zone WWR ratio of 1.07–1.25); (3) the two developed Stacking prediction models achieve R2 values greater than 0.90, substantially reducing the computational cost of dynamic simulations while ensuring high predictive accuracy; (4) SHAP analysis quantifies the contributions of 24 design parameters and 12 spatial heterogeneity indicators (HIs) to model predictions of daylighting and carbon performance. In conclusion, this study proposes heterogeneous design strategies, providing a scientific reference for the synergistic optimization of daylighting and carbon emissions in teaching buildings located in cold climates.

BuildingsVol. 16(21)
Yantai University (CN), Guangxi Arts University (CN)
Openalex Percentile: Top 18%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon