Culture-negative peritoneal dialysis-associated peritonitis rates are decreased with water lysis but not 16S rRNA gene sequencing

Objectives A successful peritoneal dialysis (PD) programme should aim to have low peritoneal dialysis-associated peritonitis (PDAP) rates. Identification of the microbial organism enables targeted antibiotic treatment and allows for a root cause analysis to be performed. Culture-negative (CN) peritonitis presents a more challenging scenario whereby empirical treatment for Gram-positive and Gram-negative organisms is commenced for 14 days, with Gram-negative cover discontinued based upon clinical response. In accordance with ISPD recommendations, we conducted a clinical quality improvement project in 2018 to decrease our culture-negative PDAP. Methods From 2018 to 2021, our department had 336 cases of PDAP. The introduction of a water-lysis step and the application of 16S rRNA gene sequencing were implemented to reduce culture-negative PDAP. Results There were 336 cases of PDAP between 2018 and 2021. In total, 135 cases occurred prior to the initiation of the water lysis step and 201 cases occurred after the introduction of the water lysis step and 16S rRNA sequencing. The rate of culture-negative PDAP prior to our change in PD effluent culture methodology was 33% (45/135); following changes to include a water lysis step and an increase in sample volume, the rate of culture-negative PDAP significantly fell to 20% (41/201) ( p < 0.01). 16S rRNA, using Sanger sequencing of culture-negative samples, did not significantly increase pathogen detection. Five out of 6 samples remained CN in the pre-water lysis step group, and 17 out of 23 samples also remained CN in the post-water lysis group ( p = 0.61). Conclusions Introduction of water lysis of peritoneal effluent significantly decreased culture-negative peritonitis rates, thus increasing organism identification and allowing for targeted antimicrobial therapy.

Authors

Institutions

Publication Details

Journal
Peritoneal Dialysis International
Published
2026-11-04
DOI
https://doi.org/10.1177/08968608261493217
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Culture-negative peritoneal dialysis-associated peritonitis rates are decreased with water lysis but not 16S rRNA gene sequencing

Ian Butler, Luxme Nadarajah, Stanley Fan, Holly Ciesielczuk et al.
Peritoneal Dialysis International
Dialysis and Renal Disease Management
article

Culture-negative peritoneal dialysis-associated peritonitis rates are decreased with water lysis but not 16S rRNA gene sequencing

Ian Butler, Luxme Nadarajah, Stanley Fan, Holly Ciesielczuk, Jonathon Lambourne
article en

Abstract

Objectives A successful peritoneal dialysis (PD) programme should aim to have low peritoneal dialysis-associated peritonitis (PDAP) rates. Identification of the microbial organism enables targeted antibiotic treatment and allows for a root cause analysis to be performed. Culture-negative (CN) peritonitis presents a more challenging scenario whereby empirical treatment for Gram-positive and Gram-negative organisms is commenced for 14 days, with Gram-negative cover discontinued based upon clinical response. In accordance with ISPD recommendations, we conducted a clinical quality improvement project in 2018 to decrease our culture-negative PDAP. Methods From 2018 to 2021, our department had 336 cases of PDAP. The introduction of a water-lysis step and the application of 16S rRNA gene sequencing were implemented to reduce culture-negative PDAP. Results There were 336 cases of PDAP between 2018 and 2021. In total, 135 cases occurred prior to the initiation of the water lysis step and 201 cases occurred after the introduction of the water lysis step and 16S rRNA sequencing. The rate of culture-negative PDAP prior to our change in PD effluent culture methodology was 33% (45/135); following changes to include a water lysis step and an increase in sample volume, the rate of culture-negative PDAP significantly fell to 20% (41/201) ( p < 0.01). 16S rRNA, using Sanger sequencing of culture-negative samples, did not significantly increase pathogen detection. Five out of 6 samples remained CN in the pre-water lysis step group, and 17 out of 23 samples also remained CN in the post-water lysis group ( p = 0.61). Conclusions Introduction of water lysis of peritoneal effluent significantly decreased culture-negative peritonitis rates, thus increasing organism identification and allowing for targeted antimicrobial therapy.

Peritoneal Dialysis International
Queen Mary University of London (GB)
Openalex Percentile: Top 14%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Culture-negative peritoneal dialysis-associated peritonitis rates are decreased with water lysis but not 16S rRNA gene sequencing — Ian Butler, Luxme Nadarajah, et al. · Peritoneal Dialysis International (2026) | TGRS Research Map | TGRS