Feature extraction for LSTM-based finger-joint angle estimation from sEMG

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-02
DOI
https://doi.org/10.48550/arxiv.2611.02736
Primary Topic
Muscle activation and electromyography studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

Marelie Hattingh Davel, Gerda Jager, Ian Thomson
arXiv (Cornell University)
Muscle activation and electromyography studies
preprint

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

Marelie Hattingh Davel, Gerda Jager, Ian Thomson
preprint en

Abstract

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

arXiv (Cornell University)
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon