Search for dark photon dark matter near $\mathbf{1\,meV}$ using a superconducting mixer

We demonstrate the use of a superconducting mixer for direct searches for dark photon dark matter (DPDM) in the meV mass range. DPDM couples to the ordinary electromagnetic field through kinetic mixing with a coupling constant $χ$ and can convert into ordinary photons at the surface of a metal plate. For DPDM masses of 1 meV, the conversion photons have frequencies of around 240 GHz. At such frequencies, superconducting mixers enable low-noise spectroscopic measurements. We performed a direct search for DPDM in the mass range 1.0047578-1.0047598 meV, corresponding to the frequency range 242.94935-242.94983 GHz, using approximately one hour of data obtained with a cryogenic millimeter-wave receiver based on a superconducting mixer. No significant excess was found, and we set upper limits of $χ< (1.6\text{-}1.9)\times10^{-9}$ at the 95% confidence level. These limits are comparable to existing constraints from solar dark photons. By applying this method, we plan to extend the search to the wider mass range of 0.7-1.1 meV, corresponding to 170-260 GHz, with improved sensitivity.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-02
DOI
https://doi.org/10.48550/arxiv.2611.02734
Primary Topic
Dark Matter and Cosmic Phenomena
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Search for dark photon dark matter near $\mathbf{1\,meV}$ using a superconducting mixer

Takaaki NAKAJIMA, Hasegawa Y, O. Tajima, J. Suzuki et al.
arXiv (Cornell University)
Dark Matter and Cosmic Phenomena
preprint

Search for dark photon dark matter near $\mathbf{1\,meV}$ using a superconducting mixer

Takaaki NAKAJIMA, Hasegawa Y, O. Tajima, J. Suzuki, S. Honda, H. Ogawa, H. Takeuchi, S. Adachi, K. Hanimura
preprint en

Abstract

We demonstrate the use of a superconducting mixer for direct searches for dark photon dark matter (DPDM) in the meV mass range. DPDM couples to the ordinary electromagnetic field through kinetic mixing with a coupling constant $χ$ and can convert into ordinary photons at the surface of a metal plate. For DPDM masses of 1 meV, the conversion photons have frequencies of around 240 GHz. At such frequencies, superconducting mixers enable low-noise spectroscopic measurements. We performed a direct search for DPDM in the mass range 1.0047578-1.0047598 meV, corresponding to the frequency range 242.94935-242.94983 GHz, using approximately one hour of data obtained with a cryogenic millimeter-wave receiver based on a superconducting mixer. No significant excess was found, and we set upper limits of $χ< (1.6\text{-}1.9)\times10^{-9}$ at the 95% confidence level. These limits are comparable to existing constraints from solar dark photons. By applying this method, we plan to extend the search to the wider mass range of 0.7-1.1 meV, corresponding to 170-260 GHz, with improved sensitivity.

arXiv (Cornell University)
Dark Matter and Cosmic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon