Transport and retention of microplastics during riverbank filtration

Introduction Riverbank filtration (RBF) is a widely used natural water treatment process; however, the fate and attenuation of microplastics (MPs), within river–aquifer systems is not well understood. This study investigated the occurrence and characteristics of MPs within an RBF system to comprehend the MPs transport behaviour. Methods Five sampling campaigns were conducted over the course of a year. These covered rivers, groundwater wells and an abstraction well across six locations within the RBF site, which extracts water from the Leine River in Germany. MPs were collected and characterized through stereomicroscopy and chemically identified using ATR-FTIR. In this study, MPs were detected throughout the RBF system but also in groundwater without river influence during all sampling campaigns, demonstrating their continuous presence and persistence within the hydrological continuum. Results and discussion River water consistently exhibited the highest MP concentration (74.4 ± 23.5 MPs/100 L), whereas the abstraction well showed low concentration (9.4 ± 7.8 MPs/100 L), significant differences in MP concentrations were observed ( p = 0.002). MP transport and retention were strongly influenced by MP characteristics such as shape and type. Overall, fiber shapes (88.5% of all particles) and polyethylene terephthalate (PET) (73.8% of total identified polymers) dominated. The prevalence of fibers suggests that their elongated morphology may enhance mobility through interconnected pore spaces. Within the collected MP size range of 20 to 5,000 μm, the most abundant class was 100–200 μm, indicating that particle size may regulate pore-scale straining. These results indicate that, despite their high density, PET fibers can pass through pore spaces and potentially bypass natural filtration barriers due to their small size. The study emphasizes that RBF is an effective spatial concentration attenuation system for reducing MP contamination in drinking water sources and highlight the importance of natural attenuation process.

Authors

Institutions

Publication Details

Journal
Frontiers in Water
Published
2026-11-03
DOI
https://doi.org/10.3389/frwa.2026.1991996
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transport and retention of microplastics during riverbank filtration

P. Janknecht, Kiran Bala, R. Nogueira, Dinesh Parida et al.
Frontiers in Water
Microplastics and Plastic Pollution
article

Transport and retention of microplastics during riverbank filtration

P. Janknecht, Kiran Bala, R. Nogueira, Dinesh Parida, Kanika Kiran
article en

Abstract

Introduction Riverbank filtration (RBF) is a widely used natural water treatment process; however, the fate and attenuation of microplastics (MPs), within river–aquifer systems is not well understood. This study investigated the occurrence and characteristics of MPs within an RBF system to comprehend the MPs transport behaviour. Methods Five sampling campaigns were conducted over the course of a year. These covered rivers, groundwater wells and an abstraction well across six locations within the RBF site, which extracts water from the Leine River in Germany. MPs were collected and characterized through stereomicroscopy and chemically identified using ATR-FTIR. In this study, MPs were detected throughout the RBF system but also in groundwater without river influence during all sampling campaigns, demonstrating their continuous presence and persistence within the hydrological continuum. Results and discussion River water consistently exhibited the highest MP concentration (74.4 ± 23.5 MPs/100 L), whereas the abstraction well showed low concentration (9.4 ± 7.8 MPs/100 L), significant differences in MP concentrations were observed ( p = 0.002). MP transport and retention were strongly influenced by MP characteristics such as shape and type. Overall, fiber shapes (88.5% of all particles) and polyethylene terephthalate (PET) (73.8% of total identified polymers) dominated. The prevalence of fibers suggests that their elongated morphology may enhance mobility through interconnected pore spaces. Within the collected MP size range of 20 to 5,000 μm, the most abundant class was 100–200 μm, indicating that particle size may regulate pore-scale straining. These results indicate that, despite their high density, PET fibers can pass through pore spaces and potentially bypass natural filtration barriers due to their small size. The study emphasizes that RBF is an effective spatial concentration attenuation system for reducing MP contamination in drinking water sources and highlight the importance of natural attenuation process.

Frontiers in WaterVol. 8
Leibniz University Hannover (DE), Enercity (Germany) (DE), Indian Institute of Technology Indore (IN)
Openalex Percentile: Top 27%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon