Energy, Exergy, and Exergoeconomic Assessment of a Combined-Cycle Power Plant

Combined-cycle gas turbine (CCGT) power plants play an important role in reducing greenhouse gas emissions while maintaining high thermal efficiency. Accurate thermodynamic models are essential for evaluating plant performance under different operating conditions and supporting improvements in energy resource management. This study presents a Python-based thermodynamic model of an isolated natural gas-fired CCGT power plant, applied to 1027 steady-state operating points recorded over one month of operation. The model integrates energy, exergy, and exergoeconomic analyses based on the Specific Exergy Costing (SPECO) methodology to assess plant operation with and without supplementary firing. The model was validated against the measured steam production, with a mean absolute percentage error of 2.8%. The proposed methodology enables the evaluation of component efficiencies, exergy destruction, cost formation, and the influence of different operating modes on electricity production. The plant achieved median gross first- and second-law efficiencies of 46.6% and 44.6%, respectively (45.1% and 43.2% on a net basis). The combustion chamber exhibited the highest exergy destruction in both operating modes, while the supplementary burner became one of the major sources of irreversibility when supplementary firing was activated. The specific exergy cost of electricity decreased from about 21.0 to 14.2 $/GJ as the electrical output increased from 11.3 to 20.9 MW, with a median of 16.47 $/GJ in the period. The supplementary burner presented the highest relative cost difference (median of 1.06), whereas the combustion chamber had the highest exergy destruction rate and cost rate of exergy destruction. The proposed model provides a flexible and reproducible framework for evaluating CCGT power plants and can support operational assessment and decision-making aimed at improving thermodynamic and economic performance.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-03
DOI
https://doi.org/10.3390/en19215268
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy, Exergy, and Exergoeconomic Assessment of a Combined-Cycle Power Plant

Taynara Geysa Silva do Lago, João Alves de Lima, Gilberto Augusto Amado Moreira, José Vinícius Santos de Araújo et al.
Energies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Energy, Exergy, and Exergoeconomic Assessment of a Combined-Cycle Power Plant

Taynara Geysa Silva do Lago, João Alves de Lima, Gilberto Augusto Amado Moreira, José Vinícius Santos de Araújo, Sidnéia Lira Cavalcante, Juan Moisés Maurício Villanueva, Gustavo Basílio Lima, Lucas Haas, E C Macedo, Ademar Virgolino da Silva Netto, Jocélio Jairo Vieira, Júlia Alves Santos
article en

Abstract

Combined-cycle gas turbine (CCGT) power plants play an important role in reducing greenhouse gas emissions while maintaining high thermal efficiency. Accurate thermodynamic models are essential for evaluating plant performance under different operating conditions and supporting improvements in energy resource management. This study presents a Python-based thermodynamic model of an isolated natural gas-fired CCGT power plant, applied to 1027 steady-state operating points recorded over one month of operation. The model integrates energy, exergy, and exergoeconomic analyses based on the Specific Exergy Costing (SPECO) methodology to assess plant operation with and without supplementary firing. The model was validated against the measured steam production, with a mean absolute percentage error of 2.8%. The proposed methodology enables the evaluation of component efficiencies, exergy destruction, cost formation, and the influence of different operating modes on electricity production. The plant achieved median gross first- and second-law efficiencies of 46.6% and 44.6%, respectively (45.1% and 43.2% on a net basis). The combustion chamber exhibited the highest exergy destruction in both operating modes, while the supplementary burner became one of the major sources of irreversibility when supplementary firing was activated. The specific exergy cost of electricity decreased from about 21.0 to 14.2 $/GJ as the electrical output increased from 11.3 to 20.9 MW, with a median of 16.47 $/GJ in the period. The supplementary burner presented the highest relative cost difference (median of 1.06), whereas the combustion chamber had the highest exergy destruction rate and cost rate of exergy destruction. The proposed model provides a flexible and reproducible framework for evaluating CCGT power plants and can support operational assessment and decision-making aimed at improving thermodynamic and economic performance.

EnergiesVol. 19(21)
Universidade Federal da Paraíba (BR), Instituto Federal de Educação Ciência e Tecnologia da Paraíba (BR)
Openalex Percentile: Top 24%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.