Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-03
DOI
https://doi.org/10.64898/2026.10.31.763347
Primary Topic
Electrochemical sensors and biosensors
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

Yasser Khan, Lama I. Almofeez, Mohammad Shafiqul Islam, Thilina S. Ambagahawaththa
bioRxiv (Cold Spring Harbor Laboratory)
Electrochemical sensors and biosensors
preprint

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

Yasser Khan, Lama I. Almofeez, Mohammad Shafiqul Islam, Thilina S. Ambagahawaththa
preprint en

Abstract

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

bioRxiv (Cold Spring Harbor Laboratory)
University of Southern California (US)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors — Yasser Khan, Lama I. Almofeez, et al. · bioRxiv (Cold Spring Harbor Laboratory) (2026) | TGRS Research Map | TGRS