A multi-reader multi-case study comparing Breast Cancer Reading Efficiency and Accuracy in Screening with Tomosynthesis versus AI-assisted mammography

OBJECTIVES: Full-field digital mammography (FFDM) is the standard for breast cancer screening but has reduced sensitivity in dense breasts. Digital breast tomosynthesis (DBT) improves cancer detection compared to 2D mammography but is limited by cost and longer reading times. Artificial intelligence (AI)-enhanced mammography has demonstrated improved sensitivity compared to 2D mammography. This study compares AI-enhanced 2D mammography (DM+AI) with DBT in recalling interval breast cancers (IBCs). METHODS: : A multi-reader, multi-case crossover study was conducted using the Emory BrEast Imaging Dataset, which includes paired FFDM and DBT images with biopsy-proven outcomes. Six radiologists reviewed 53 IBC and 53 screen-detected cancer (SDC) cases, with random assignment to DM+AI or DBT, followed by crossover after a washout period. Primary outcomes included recall rate of IBCs. Secondary outcomes included recall rate of SDCs, interpretation time, and subgroup analysis by breast density. RESULTS: : For IBCs, DM+AI and DBT demonstrated similar recall rates (41.5% vs 40.9%) and detection rates (14.8% vs 11.9%). DM+AI identified more non-invasive (31.5% vs 13.0%) and mass-forming (61.0% vs 21.8%) cancers. For SDCs, recall and detection rates were comparable across modalities. In fatty breasts, recall was higher with DM+AI (91.7% vs 50.0%), while DBT performed better in extremely dense breasts. DM+AI enabled faster interpretation, averaging 24.1 seconds less per case. CONCLUSION: : AI-enhanced 2D mammography demonstrated comparable performance to DBT with shorter interpretation times, supporting a stratified screening approach. ADVANCES IN KNOWLEDGE: This study is the first direct comparison of AI-enhanced mammography and digital breast tomosynthesis for IBC detection.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-11-02
DOI
https://doi.org/10.1093/bjr/tqag264
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multi-reader multi-case study comparing Breast Cancer Reading Efficiency and Accuracy in Screening with Tomosynthesis versus AI-assisted mammography

Zheng Long Lim, Aawez Mansuri, Pooja Jagmohan, Wynne Yuru Chua et al.
British Journal of Radiology
Digital Radiography and Breast Imaging
article

A multi-reader multi-case study comparing Breast Cancer Reading Efficiency and Accuracy in Screening with Tomosynthesis versus AI-assisted mammography

Zheng Long Lim, Aawez Mansuri, Pooja Jagmohan, Wynne Yuru Chua, Mikael Hartman, Shuliang Ge, Rohan Isaac, Hari Trivedi, Samuel Lau, Ying Mei Wong, Han Yang Ong, Bee Choo Tai, Judy Wawira Gichoya, Beatrice Brown-Mulry, Serene Goh Si Ning, Du Hao, Mengling Feng, Edward Seah, Ganga Chandrasegan
article en

Abstract

OBJECTIVES: Full-field digital mammography (FFDM) is the standard for breast cancer screening but has reduced sensitivity in dense breasts. Digital breast tomosynthesis (DBT) improves cancer detection compared to 2D mammography but is limited by cost and longer reading times. Artificial intelligence (AI)-enhanced mammography has demonstrated improved sensitivity compared to 2D mammography. This study compares AI-enhanced 2D mammography (DM+AI) with DBT in recalling interval breast cancers (IBCs). METHODS: : A multi-reader, multi-case crossover study was conducted using the Emory BrEast Imaging Dataset, which includes paired FFDM and DBT images with biopsy-proven outcomes. Six radiologists reviewed 53 IBC and 53 screen-detected cancer (SDC) cases, with random assignment to DM+AI or DBT, followed by crossover after a washout period. Primary outcomes included recall rate of IBCs. Secondary outcomes included recall rate of SDCs, interpretation time, and subgroup analysis by breast density. RESULTS: : For IBCs, DM+AI and DBT demonstrated similar recall rates (41.5% vs 40.9%) and detection rates (14.8% vs 11.9%). DM+AI identified more non-invasive (31.5% vs 13.0%) and mass-forming (61.0% vs 21.8%) cancers. For SDCs, recall and detection rates were comparable across modalities. In fatty breasts, recall was higher with DM+AI (91.7% vs 50.0%), while DBT performed better in extremely dense breasts. DM+AI enabled faster interpretation, averaging 24.1 seconds less per case. CONCLUSION: : AI-enhanced 2D mammography demonstrated comparable performance to DBT with shorter interpretation times, supporting a stratified screening approach. ADVANCES IN KNOWLEDGE: This study is the first direct comparison of AI-enhanced mammography and digital breast tomosynthesis for IBC detection.

British Journal of Radiology
Emory University (US), National University of Singapore (SG), Emory University Hospital (US), National University Hospital (SG), National University Health System (SG)
Openalex Percentile: Top 13%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.