Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs

The present research concentrates on finding the optimum outrigger location in a 60-storey non-orthogonal reinforced cement concrete (RCC) high-rise structure subjected to wind loads, considering variations in seismic zones and soil conditions. The building is modelled and analyzed using ETABS, with three different outrigger configurations located at 0.3H, 0.56H, and 0.75H. The structural behavior is examined under varying wind-speed conditions associated with the selected seismic zones and soil classifications. The analytical results indicates that changes in seismic zone and soil type do not influence the modal time period of the structure. Among the configurations considered, the outrigger system placed at 0.3H demonstrates better performance in controlling the building deflection. The findings emphasize that the strategic placement of outriggers plays a significant role in enhancing the lateral stability and overall wind-resistant performance of non-orthogonal high-rise RCC buildings.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-03
DOI
https://doi.org/10.5281/zenodo.23909346
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs

Jitendra Dalvi, Vivek A. Sali, Prof. Nagesh Shelke
Zenodo (CERN European Organization for Nuclear Research)
Seismic and Structural Analysis of Tall Buildings
article

Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs

Jitendra Dalvi, Vivek A. Sali, Prof. Nagesh Shelke
article en

Abstract

The present research concentrates on finding the optimum outrigger location in a 60-storey non-orthogonal reinforced cement concrete (RCC) high-rise structure subjected to wind loads, considering variations in seismic zones and soil conditions. The building is modelled and analyzed using ETABS, with three different outrigger configurations located at 0.3H, 0.56H, and 0.75H. The structural behavior is examined under varying wind-speed conditions associated with the selected seismic zones and soil classifications. The analytical results indicates that changes in seismic zone and soil type do not influence the modal time period of the structure. Among the configurations considered, the outrigger system placed at 0.3H demonstrates better performance in controlling the building deflection. The findings emphasize that the strategic placement of outriggers plays a significant role in enhancing the lateral stability and overall wind-resistant performance of non-orthogonal high-rise RCC buildings.

Zenodo (CERN European Organization for Nuclear Research)
DY Patil Deemed to be University (IN)
Openalex Percentile: Top 20%
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Effective Positioning of Outrigger in Non- Orthogonal Rcc High-Rise Building under Wind Loading for Different Seismic Zones and Soil Conditions using Etabs — Jitendra Dalvi, Vivek A. Sali, et al. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS