Geoelectrical Investigation of Groundwater Potential around the Cattle Yard, Ovia North-East Local Government Area, Edo State, Nigeria

Groundwater scarcity around the Cattle Yard in Ovia North-East Local Government Area, Edo State, Nigeria, necessitates investigation to identify geoelectric conditions that may support groundwater occurrence. A vertical electrical sounding (VES) survey was conducted using a Parsi (A.C) Earth Resistivity Meter, and the Schlumberger electrode configuration with a maximum current electrode separation (AB) of 500m. The geodetic coordinates of the vertical electrical station were recorded using a Global Positioning System (GPS). The VES data collected during the field survey were processed and interpreted using IPI2WIN software. Six subsurface geoelectric layers were interpreted with layer boundaries occurring at depths of approximately 0.916m, 1.02m, 2.34m, 7.47m, and 24.40m. Resistivity values range from 0.675Ωm to 126912Ωm, indicating marked electrical heterogeneity. The interpreted units comprise materials tentatively associated with cemented sandstone or gravel, dry sand or lateritic gravel, wet or saturated sand, and lateritic or sandy material. The fifth layer with a resistivity of 146 Ωm and a thickness of 16.9m may represent a relatively conductive sandy or lateritic interval that could have groundwater bearing potential. However, resistivity alone cannot establish saturation or aquifer productivity. The sixth layer has an undefined thickness and depth and exceptionally low resistivity of 0.675 Ωm. It is therefore interpreted conservatively as a highly conductive zone that may reflect clay rich material, mineralized water or another conductive lithology. The results provide a preliminary geoelectrical basis for groundwater assessment, but confirmation through borehole drilling, lithological logging and groundwater quality testing is required before development decisions are made.

Authors

Publication Details

Journal
FUDMA Journal of Sciences
Published
2026-11-03
DOI
https://doi.org/10.33003/fjs-2026-1022-6279
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geoelectrical Investigation of Groundwater Potential around the Cattle Yard, Ovia North-East Local Government Area, Edo State, Nigeria

Promise Odigwe, Paul Alufar, Matthew Jackson-Abara
FUDMA Journal of Sciences
Geophysical and Geoelectrical Methods
article

Geoelectrical Investigation of Groundwater Potential around the Cattle Yard, Ovia North-East Local Government Area, Edo State, Nigeria

Promise Odigwe, Paul Alufar, Matthew Jackson-Abara
article en

Abstract

Groundwater scarcity around the Cattle Yard in Ovia North-East Local Government Area, Edo State, Nigeria, necessitates investigation to identify geoelectric conditions that may support groundwater occurrence. A vertical electrical sounding (VES) survey was conducted using a Parsi (A.C) Earth Resistivity Meter, and the Schlumberger electrode configuration with a maximum current electrode separation (AB) of 500m. The geodetic coordinates of the vertical electrical station were recorded using a Global Positioning System (GPS). The VES data collected during the field survey were processed and interpreted using IPI2WIN software. Six subsurface geoelectric layers were interpreted with layer boundaries occurring at depths of approximately 0.916m, 1.02m, 2.34m, 7.47m, and 24.40m. Resistivity values range from 0.675Ωm to 126912Ωm, indicating marked electrical heterogeneity. The interpreted units comprise materials tentatively associated with cemented sandstone or gravel, dry sand or lateritic gravel, wet or saturated sand, and lateritic or sandy material. The fifth layer with a resistivity of 146 Ωm and a thickness of 16.9m may represent a relatively conductive sandy or lateritic interval that could have groundwater bearing potential. However, resistivity alone cannot establish saturation or aquifer productivity. The sixth layer has an undefined thickness and depth and exceptionally low resistivity of 0.675 Ωm. It is therefore interpreted conservatively as a highly conductive zone that may reflect clay rich material, mineralized water or another conductive lithology. The results provide a preliminary geoelectrical basis for groundwater assessment, but confirmation through borehole drilling, lithological logging and groundwater quality testing is required before development decisions are made.

FUDMA Journal of SciencesVol. 10(22)
Openalex Percentile: Top 19%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon