Ion Valence Difference Governs Membrane Charge Preference in Nanofiltration-Based Radionuclide Separation

Abstract Selective separation of radionuclides with varying environmental hazards is critical for mitigating the disposal burden of high-level radioactive wastewater. Although positively charged (PC) membranes are generally considered effective for cation pair separation, the applicability of negatively charged (NC) membranes for separating cations with large valence differences remains unresolved. In this study, Ag+/Zr4+ and Ag+/Sr2+ were used as representative radionuclides with large and small valence differences, respectively, to evaluate the separation performance and underlying mechanisms of PC and NC membranes. Notably, NC membranes maintained near-complete rejection of Zr4+ while simultaneously exhibiting higher Ag+ permeability, thereby achieving superior Ag+/Zr4+ selectivity relative to PC membranes. DFT calculations and MD simulations revealed that strong ion–membrane interactions facilitated preferential partitioning of Zr4+ at the NC membrane interface, whereas differences in hydration energy governed the competitive transport of Ag+ and Zr4+. Furthermore, Zr4+ accumulated at the membrane surface induced incomplete dehydration of Ag+, reducing interfacial transport barriers and promoting Ag+ permeation. Comparative analysis of Ag+/Zr4+ and Ag+/Sr2+ systems further demonstrated that ion valence difference governs the preference of membrane charges: NC membranes are preferred for M+/M4+ separations, whereas PC membranes are preferred for M+/M2+ separations, which was further validated by Li+/Mg2+ and Li+/Ti4+ separations. These findings clarify the mechanistic distinction between co-ion and counterion competition, providing guidance for the selection of membrane charge types for energy-efficient radionuclide separation and selective resource recovery beyond the nuclear industry.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2026-11-04
DOI
https://doi.org/10.1021/acs.est.6c14615
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ion Valence Difference Governs Membrane Charge Preference in Nanofiltration-Based Radionuclide Separation

郭云, Xinwei Wang, Li Ares Wang, Zhiwei Wang et al.
Environmental Science & Technology
Membrane Separation Technologies
article

Ion Valence Difference Governs Membrane Charge Preference in Nanofiltration-Based Radionuclide Separation

郭云, Xinwei Wang, Li Ares Wang, Zhiwei Wang, Rui Wang, Meng Sheng
article en

Abstract

Abstract Selective separation of radionuclides with varying environmental hazards is critical for mitigating the disposal burden of high-level radioactive wastewater. Although positively charged (PC) membranes are generally considered effective for cation pair separation, the applicability of negatively charged (NC) membranes for separating cations with large valence differences remains unresolved. In this study, Ag+/Zr4+ and Ag+/Sr2+ were used as representative radionuclides with large and small valence differences, respectively, to evaluate the separation performance and underlying mechanisms of PC and NC membranes. Notably, NC membranes maintained near-complete rejection of Zr4+ while simultaneously exhibiting higher Ag+ permeability, thereby achieving superior Ag+/Zr4+ selectivity relative to PC membranes. DFT calculations and MD simulations revealed that strong ion–membrane interactions facilitated preferential partitioning of Zr4+ at the NC membrane interface, whereas differences in hydration energy governed the competitive transport of Ag+ and Zr4+. Furthermore, Zr4+ accumulated at the membrane surface induced incomplete dehydration of Ag+, reducing interfacial transport barriers and promoting Ag+ permeation. Comparative analysis of Ag+/Zr4+ and Ag+/Sr2+ systems further demonstrated that ion valence difference governs the preference of membrane charges: NC membranes are preferred for M+/M4+ separations, whereas PC membranes are preferred for M+/M2+ separations, which was further validated by Li+/Mg2+ and Li+/Ti4+ separations. These findings clarify the mechanistic distinction between co-ion and counterion competition, providing guidance for the selection of membrane charge types for energy-efficient radionuclide separation and selective resource recovery beyond the nuclear industry.

Environmental Science & Technology
Tongji University (CN)
Openalex Percentile: Top 27%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Ion Valence Difference Governs Membrane Charge Preference in Nanofiltration-Based Radionuclide Separation — 郭云, Xinwei Wang, et al. · Environmental Science & Technology (2026) | TGRS Research Map | TGRS