Particle picking and centering in cryo-electron micrographs via a vanishing radial kernel

A training-free procedure combines particle picking and approximate centering in cryo-electron microscopy through a single convolution of the micrograph with a compact radial kernel, whose weights increase with distance from the origin, saturate in an annulus, and vanish beyond it. Particles are darker than their surroundings and much weaker than the noise; each carves a well in the response, and local minima of the response are candidate centers. Constant background offsets leave these extrema unchanged away from image boundaries, and a local stability bound controls the displacement of a well's minimum under signed perturbations without assuming a symmetric particle. Grid seeds are iteratively updated, nearby endpoints are merged, and two-dimensional classification follows. On the \emph{Plasmodium falciparum} 80S ribosome and $\beta$-galactosidase data sets, reconstructions reach 3.68 and 4.30~\AA{}, compared with 3.77 and 4.36~\AA{} using reference coordinates, with picking at 0.20--0.26~s per micrograph.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-03
DOI
https://doi.org/10.64898/2026.11.02.763610
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Particle picking and centering in cryo-electron micrographs via a vanishing radial kernel

Ayelet Heimowitz, Nir Sharon
bioRxiv (Cold Spring Harbor Laboratory)
Advanced Electron Microscopy Techniques and Applications
preprint

Particle picking and centering in cryo-electron micrographs via a vanishing radial kernel

Ayelet Heimowitz, Nir Sharon
preprint en

Abstract

A training-free procedure combines particle picking and approximate centering in cryo-electron microscopy through a single convolution of the micrograph with a compact radial kernel, whose weights increase with distance from the origin, saturate in an annulus, and vanish beyond it. Particles are darker than their surroundings and much weaker than the noise; each carves a well in the response, and local minima of the response are candidate centers. Constant background offsets leave these extrema unchanged away from image boundaries, and a local stability bound controls the displacement of a well's minimum under signed perturbations without assuming a symmetric particle. Grid seeds are iteratively updated, nearby endpoints are merged, and two-dimensional classification follows. On the \emph{Plasmodium falciparum} 80S ribosome and $\beta$-galactosidase data sets, reconstructions reach 3.68 and 4.30~\AA{}, compared with 3.77 and 4.36~\AA{} using reference coordinates, with picking at 0.20--0.26~s per micrograph.

bioRxiv (Cold Spring Harbor Laboratory)
Tel Aviv University (IL), Ariel University (IL)
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Particle picking and centering in cryo-electron micrographs via a vanishing radial kernel — Ayelet Heimowitz, Nir Sharon · bioRxiv (Cold Spring Harbor Laboratory) (2026) | TGRS Research Map | TGRS