ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 T

BACKGROUND: 3D-FLAIR is central to MR-based diagnosis and monitoring of MS, but long acquisition times remain a limitation. OBJECTIVES: This single-center prospective non-inferiority study evaluated whether compressed sensing (CS) - accelerated 3D-FLAIR at 1.5T provides lesion detection comparable to optimized Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) - accelerated 3D-FLAIR. Optimized CS- and GRAPPA-accelerated 3D-FLAIR sequences were incorporated into MRI examinations in patients with known or suspected MS. The primary endpoint was manual lesion count by two blinded readers using a 10% non-inferiority margin. Secondary endpoints included image quality, SNR, CNR, and automated lesion count and volumetry. RESULTS: Sixty-eight patients were included (mean age, 40.1+/-13.3 years; 61.8% women). CS-accelerated 3D-FLAIR reduced acquisition time by 31.8% compared with GRAPPA (4:00 vs 5:52 minutes). Non-inferiority for manual lesion count was demonstrated for both readers (reader A, p < .0001; reader B, p = .005). Interrater agreement was excellent for CS (ICC = 0.921; 95% CI, 0.837-0.957) and very good for GRAPPA (ICC = 0.851; 95% CI, 0.769-0.906). Subjective image quality was high for both techniques. GRAPPA showed higher objective signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR), whereas automated lesion counts and volumes were higher for CS. CONCLUSION: CS-accelerated 3D-FLAIR provided non-inferior lesion detection with substantial scan-time reduction.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-03
DOI
https://doi.org/10.64898/2026.11.02.26367062
Primary Topic
Advanced MRI Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 T

O M Alykova, Sigrid Reuter, Benedikt Sundermann, Maike Gerdes et al.
medRxiv
Advanced MRI Techniques and Applications
preprint

ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 T

O M Alykova, Sigrid Reuter, Benedikt Sundermann, Maike Gerdes, Catalin George Iacoban, Christian Mathys, Holger Bösenberg, Claudia Klüner
preprint en

Abstract

BACKGROUND: 3D-FLAIR is central to MR-based diagnosis and monitoring of MS, but long acquisition times remain a limitation. OBJECTIVES: This single-center prospective non-inferiority study evaluated whether compressed sensing (CS) - accelerated 3D-FLAIR at 1.5T provides lesion detection comparable to optimized Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) - accelerated 3D-FLAIR. Optimized CS- and GRAPPA-accelerated 3D-FLAIR sequences were incorporated into MRI examinations in patients with known or suspected MS. The primary endpoint was manual lesion count by two blinded readers using a 10% non-inferiority margin. Secondary endpoints included image quality, SNR, CNR, and automated lesion count and volumetry. RESULTS: Sixty-eight patients were included (mean age, 40.1+/-13.3 years; 61.8% women). CS-accelerated 3D-FLAIR reduced acquisition time by 31.8% compared with GRAPPA (4:00 vs 5:52 minutes). Non-inferiority for manual lesion count was demonstrated for both readers (reader A, p < .0001; reader B, p = .005). Interrater agreement was excellent for CS (ICC = 0.921; 95% CI, 0.837-0.957) and very good for GRAPPA (ICC = 0.851; 95% CI, 0.769-0.906). Subjective image quality was high for both techniques. GRAPPA showed higher objective signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR), whereas automated lesion counts and volumes were higher for CS. CONCLUSION: CS-accelerated 3D-FLAIR provided non-inferior lesion detection with substantial scan-time reduction.

medRxiv
Evangelisches Krankenhaus Oldenburg (DE)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 T — O M Alykova, Sigrid Reuter, et al. · medRxiv (2026) | TGRS Research Map | TGRS