AIoT-Based Smart Classroom Energy Optimization and Occupancy Monitoring System

Lights and fans in many classrooms keep running after the last student has left, or while daylight is already enough, which raises electricity bills for no benefit. Earlier smart-building studies usually either measure energy or switch appliances, and few of them join occupancy sensing, a learned decision model and an inexpensive working prototype. This paper describes an AIoT prototype for a laboratory-scale classroom. An ESP32 board reads IR seat sensors, an LDR and a DHT22 sensor, and a Random Forest classifier, trained on 1,050 cleaned records with an 80:20 split, predicts whether the light and the fan should be on. The model reached 96.2% accuracy on the held-out data, with precision and recall between 94.3% and 95.8%, and fixed thresholds (light level ≤ 250, temperature ≥ 28 °C) keep the behaviour predictable. The circuit was simulated on the Velxio platform, the prototype was demonstrated at the project exhibition on 17 October 2026, and its approximate cost is Rs. 1,960. Comparing always-on operation with controlled operation suggests savings of roughly 40–60%, but this is an estimate that still needs metered confirmation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-03
DOI
https://doi.org/10.5281/zenodo.23908709
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AIoT-Based Smart Classroom Energy Optimization and Occupancy Monitoring System

Bhakti Gore, Vishal Puranik, Akanksha Yelmate, Amruta Sangtani
Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
article

AIoT-Based Smart Classroom Energy Optimization and Occupancy Monitoring System

Bhakti Gore, Vishal Puranik, Akanksha Yelmate, Amruta Sangtani
article en

Abstract

Lights and fans in many classrooms keep running after the last student has left, or while daylight is already enough, which raises electricity bills for no benefit. Earlier smart-building studies usually either measure energy or switch appliances, and few of them join occupancy sensing, a learned decision model and an inexpensive working prototype. This paper describes an AIoT prototype for a laboratory-scale classroom. An ESP32 board reads IR seat sensors, an LDR and a DHT22 sensor, and a Random Forest classifier, trained on 1,050 cleaned records with an 80:20 split, predicts whether the light and the fan should be on. The model reached 96.2% accuracy on the held-out data, with precision and recall between 94.3% and 95.8%, and fixed thresholds (light level ≤ 250, temperature ≥ 28 °C) keep the behaviour predictable. The circuit was simulated on the Velxio platform, the prototype was demonstrated at the project exhibition on 17 October 2026, and its approximate cost is Rs. 1,960. Comparing always-on operation with controlled operation suggests savings of roughly 40–60%, but this is an estimate that still needs metered confirmation.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 18%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon