Photoacoustic technologies for exhaled-breath analysis: A systematic review of analytical performance and reporting quality

Abstract Photoacoustic breath sensing is usually assessed mainly on the basis of its detection limit, even though the review of the literature presented here shows that analytical sensitivity is no longer the only factor that affects the comparison of studies across different sources. This review, which is aligned with PRISMA and focuses on the instrument, comprised 131 independent study families providing a total of 209 study-analyte entries. When operating under conventional real-time conditions, the lowest detection limits recorded were 1 ppbv for ammonia, 2.1 ppbv for methane, 6 ppbv for ethylene, and 1.5 ppbv for carbon monoxide. Systems that used adsorbents or enrichment reported even lower values, such as 0.465 ppbv for nitric oxide and 0.0235 ppbv for acetone, but these measurements cover the entire detection cycle and were therefore kept apart from the uninterrupted real-time measurements. Reporting completeness was much less consistent: in 59 of the 212 entries the averaging time was given, humidity control was mentioned in 54, and end-tidal sampling was reported in only 9; just 48 entries satisfied the criterion of having comparable units with a stated time base. By applying a five-domain framework for assessing reporting quality with predefined scoring rules, 66% of the study families were rated as having a High concern regarding analytical validity and 65% had a High concern about sampling control, while only one family provided all of the environmental conditions at the measurement cell. The evidence also divided into three different operational regimes, each with its own figure of merit, so that a single ranking according to detection limit is not appropriate. We therefore suggest an eight-item minimum reporting set and identify normalized noise-equivalent absorption, Allan-deviation reporting, and inter-laboratory round-robin studies as the most practical priorities for improving comparability in future breath-sensing studies.

Authors

Institutions

Publication Details

Journal
Journal of Breath Research
Published
2026-11-03
DOI
https://doi.org/10.1088/1752-7163/aebd11
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photoacoustic technologies for exhaled-breath analysis: A systematic review of analytical performance and reporting quality

Tomasz Starecki, Farzaneh Jamee, Amir Mohammad Sheikhveisi, Qazal Sheikhveisi
Journal of Breath Research
Spectroscopy and Laser Applications
article

Photoacoustic technologies for exhaled-breath analysis: A systematic review of analytical performance and reporting quality

Tomasz Starecki, Farzaneh Jamee, Amir Mohammad Sheikhveisi, Qazal Sheikhveisi
article en

Abstract

Abstract Photoacoustic breath sensing is usually assessed mainly on the basis of its detection limit, even though the review of the literature presented here shows that analytical sensitivity is no longer the only factor that affects the comparison of studies across different sources. This review, which is aligned with PRISMA and focuses on the instrument, comprised 131 independent study families providing a total of 209 study-analyte entries. When operating under conventional real-time conditions, the lowest detection limits recorded were 1 ppbv for ammonia, 2.1 ppbv for methane, 6 ppbv for ethylene, and 1.5 ppbv for carbon monoxide. Systems that used adsorbents or enrichment reported even lower values, such as 0.465 ppbv for nitric oxide and 0.0235 ppbv for acetone, but these measurements cover the entire detection cycle and were therefore kept apart from the uninterrupted real-time measurements. Reporting completeness was much less consistent: in 59 of the 212 entries the averaging time was given, humidity control was mentioned in 54, and end-tidal sampling was reported in only 9; just 48 entries satisfied the criterion of having comparable units with a stated time base. By applying a five-domain framework for assessing reporting quality with predefined scoring rules, 66% of the study families were rated as having a High concern regarding analytical validity and 65% had a High concern about sampling control, while only one family provided all of the environmental conditions at the measurement cell. The evidence also divided into three different operational regimes, each with its own figure of merit, so that a single ranking according to detection limit is not appropriate. We therefore suggest an eight-item minimum reporting set and identify normalized noise-equivalent absorption, Allan-deviation reporting, and inter-laboratory round-robin studies as the most practical priorities for improving comparability in future breath-sensing studies.

Journal of Breath Research
Warsaw University of Technology (PL), Razi University (IR), Amirkabir University of Technology (IR)
Openalex Percentile: Top 29%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon