Chip-Integrated Optical Modulation Biosensing with Microfluidic Background Reduction for High-Sensitivity Fluorescence Immunoassays
Microfluidic fluorescence immunoassays enable sensitive biomarker detection, but performance is limited by inefficient capture on planar surfaces and background fluorescence from unbound labels. Here, we present chip-based optical modulation biosensing (Chip-OMB), combining three-dimensional magnetic bead-based target capture, bead immobilization, internal fluid flushing, and modulated optical background subtraction. Magnetic beads are concentrated and immobilized in the chamber, while controlled on-chip flushing displaces unbound fluorescent labels without requiring user-performed washing after chip loading. Alternating optical interrogation of the bead cluster and surrounding solution enables background subtraction. Using fluorescently labeled magnetic beads, Chip-OMB achieved limits of detection of 0.1 pM in buffer and 22 pM in undiluted plasma, corresponding to 580-fold and 22-fold lower equivalent fluorophore-concentration limits of detection, respectively, than conventional steady-state bulk fluorescence measurements using a plate reader. Measurements correlated with the laboratory optical modulation biosensing system (R2 = 0.98). In an anti-dengue virus serotype 2 (DENV-2) nonstructural protein 1 (NS1) immunoglobulin G (IgG) immunoassay, Chip-OMB achieved a 3 ng/mL limit of detection with a ~4-log dynamic range. Among 56 sera, 29 DENV-2 cases confirmed by reverse transcription quantitative polymerase chain reaction (RT-qPCR) were Panbio IgG-positive and above the exploratory Chip-OMB cutoff, while all 27 study-defined negative controls were below it.
Authors
- Ravit Koren
- Yaniv Lustig (ORCID: https://orcid.org/0000-0001-7949-5912)
- Le Thi Hoi
- Tran Mai Hoa
- Amos Danielli (ORCID: https://orcid.org/0000-0002-4091-0493)
- Eli Schwartz (ORCID: https://orcid.org/0000-0002-4673-9084)
- Victoria Indenbaum (ORCID: https://orcid.org/0000-0002-7675-0591)
- Shmuel Burg (ORCID: https://orcid.org/0000-0002-5232-5961)
- Meir Cohen
- Nguyen Cong Hoan
- Nguyen Vu Trung (ORCID: https://orcid.org/0000-0001-6491-2808)
- Sophie Terenteva
- Tong Thi Kim Tuyen
- Reut Ashkenazy
- Huyen Ma Thi (ORCID: https://orcid.org/0009-0006-6333-8764)
Institutions
- Bar-Ilan University (IL)
- Hanoi Medical University (VN)
- Sheba Medical Center (IL)
- Israel Ministry of Health (IL)
- Institut Pasteur in Ho Chi Minh City (VN)
Publication Details
- Journal
- Biosensors
- Published
- 2026-11-02
- DOI
- https://doi.org/10.3390/bios16110623
- Primary Topic
- Microfluidic and Capillary Electrophoresis Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00