Effects of Flame-Retardant Treatment on the Fire Behavior of Upholstered Sofas in a Residential Building in Brazil

Residential fires cause substantial fatalities worldwide, yet upholstered furniture in Brazil rarely incorporates flame retardants (FR). This study evaluated the fire performance of a standard FR-free Brazilian sofa and compared it with an FR-treated sofa from the United Kingdom via full-scale compartment tests. The masonry enclosure was instrumented with thermocouples, heat flux gauges, and a residential smoke alarm. For the FR-free sofa, the smoke alarm activated at 1 min 47 s; temperatures measured at a height of 1.5 m exceeded 513 °C within 7 min 12 s, with the total heat flux approaching 22 kW/m2 and the 100 °C tenability threshold reached at 2 min 34 s (leaving only 47 s for post-alarm egress). In contrast, the FR-treated sofa suppressed initial fire spread for over 10 min, delaying alarm activation to 4 min 01 s and the 100 °C threshold to 14 min 42 s, extending safe evacuation time to 10 min 41 s. Peak thermal conditions (373 °C; 12.2 kW/m2) were deferred beyond 24 min. The FR-treated sofa substantially enhanced occupant survivability and increased the probability of fire suppression crews intervening during the incipient phase within standard NFPA 1710 response deployment timelines.

Authors

Publication Details

Journal
Fire
Published
2026-11-02
DOI
https://doi.org/10.3390/fire9110481
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Flame-Retardant Treatment on the Fire Behavior of Upholstered Sofas in a Residential Building in Brazil

Cristiano Corrêa, George Braga, Joaquim Pereira Lisboa Neto
Fire
Fire dynamics and safety research
article

Effects of Flame-Retardant Treatment on the Fire Behavior of Upholstered Sofas in a Residential Building in Brazil

Cristiano Corrêa, George Braga, Joaquim Pereira Lisboa Neto
article en

Abstract

Residential fires cause substantial fatalities worldwide, yet upholstered furniture in Brazil rarely incorporates flame retardants (FR). This study evaluated the fire performance of a standard FR-free Brazilian sofa and compared it with an FR-treated sofa from the United Kingdom via full-scale compartment tests. The masonry enclosure was instrumented with thermocouples, heat flux gauges, and a residential smoke alarm. For the FR-free sofa, the smoke alarm activated at 1 min 47 s; temperatures measured at a height of 1.5 m exceeded 513 °C within 7 min 12 s, with the total heat flux approaching 22 kW/m2 and the 100 °C tenability threshold reached at 2 min 34 s (leaving only 47 s for post-alarm egress). In contrast, the FR-treated sofa suppressed initial fire spread for over 10 min, delaying alarm activation to 4 min 01 s and the 100 °C threshold to 14 min 42 s, extending safe evacuation time to 10 min 41 s. Peak thermal conditions (373 °C; 12.2 kW/m2) were deferred beyond 24 min. The FR-treated sofa substantially enhanced occupant survivability and increased the probability of fire suppression crews intervening during the incipient phase within standard NFPA 1710 response deployment timelines.

FireVol. 9(11)
Openalex Percentile: Top 15%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon