Clinical Trial: Capsule Sponge as a Non‐Endoscopic Monitoring Tool in Eosinophilic Oesophagitis—A Prospective Real–World Multicentre Study

BACKGROUND AND AIMS: Eosinophilic oesophagitis (EoE) is a chronic inflammatory condition requiring repeat endoscopy and biopsy for histological monitoring, which is invasive, resource-intensive and burdensome for patients. The capsule sponge (CS) offers a potential non-invasive alternative. We evaluated the diagnostic accuracy, feasibility and patient acceptability of CS versus endoscopic biopsies for monitoring disease activity in adult patients. METHODS: on endoscopic biopsy histology and CS respectively. Symptom burden was assessed using the Dysphagia Symptom Questionnaire, endoscopic severity using the EoE Endoscopic Reference Score and patient acceptability via structured questionnaire. RESULTS: 136 patients (164 paired episodes) from three secondary care hospitals successfully swallowed CS with sufficient sampling; CS swallowing success rate was 92.7%. Median age was 45 years (IQR 34.8-56); 92/136 (67.6%) were male. CS demonstrated sensitivity 76.3%, specificity 89.5%, PPV 80.4%, NPV 87.0% and overall accuracy 84.8% (Cohen's κ = 0.67). AUC was 0.904 (95% CI 0.856-0.953). Patient acceptability recorded 96.7% found CS acceptable, 78.8% preferred it over endoscopy, and 90.8% would repeat the procedure. No complications occurred. CONCLUSIONS: CS is a safe, feasible, accurate and highly acceptable less-invasive tool for monitoring EoE. Its implementation could improve care pathways, reducing the need for repeated endoscopic biopsies while maintaining diagnostic reliability, with potential to reduce service burden, carbon emissions and improve patient experience. TRIAL REGISTRATION: CoSiE: IRAS number: 314770; ClinicalTrials.gov identifier: NCT06501274; QuBiE: UK Clinical Trial registry identifier: ISRCTN14071734; Trial number: 10083253.

Authors

Institutions

Publication Details

Journal
Alimentary Pharmacology & Therapeutics
Published
2026-11-03
DOI
https://doi.org/10.1111/apt.71080
Primary Topic
Eosinophilic Esophagitis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Trial: Capsule Sponge as a Non‐Endoscopic Monitoring Tool in Eosinophilic Oesophagitis—A Prospective Real–World Multicentre Study

Sarah Killcoyne, Radina Georgieva, Lisa Mears, Pearl Baker et al.
Alimentary Pharmacology & Therapeutics
Eosinophilic Esophagitis
article

Clinical Trial: Capsule Sponge as a Non‐Endoscopic Monitoring Tool in Eosinophilic Oesophagitis—A Prospective Real–World Multicentre Study

Sarah Killcoyne, Radina Georgieva, Lisa Mears, Pearl Baker, Guiomar Moral Villarejo, Anjan Dhar, Jacobo Ortiz‐Fernández‐Sordo, Francoise Cole, Kim Shaw, Ashraf Sanduka, RB Vinod Kumar, Danielle L. Morris, Maria O’Donovan, Hyesha McDonald, Erzsebet Santa, Ayesha Rai
article en

Abstract

BACKGROUND AND AIMS: Eosinophilic oesophagitis (EoE) is a chronic inflammatory condition requiring repeat endoscopy and biopsy for histological monitoring, which is invasive, resource-intensive and burdensome for patients. The capsule sponge (CS) offers a potential non-invasive alternative. We evaluated the diagnostic accuracy, feasibility and patient acceptability of CS versus endoscopic biopsies for monitoring disease activity in adult patients. METHODS: on endoscopic biopsy histology and CS respectively. Symptom burden was assessed using the Dysphagia Symptom Questionnaire, endoscopic severity using the EoE Endoscopic Reference Score and patient acceptability via structured questionnaire. RESULTS: 136 patients (164 paired episodes) from three secondary care hospitals successfully swallowed CS with sufficient sampling; CS swallowing success rate was 92.7%. Median age was 45 years (IQR 34.8-56); 92/136 (67.6%) were male. CS demonstrated sensitivity 76.3%, specificity 89.5%, PPV 80.4%, NPV 87.0% and overall accuracy 84.8% (Cohen's κ = 0.67). AUC was 0.904 (95% CI 0.856-0.953). Patient acceptability recorded 96.7% found CS acceptable, 78.8% preferred it over endoscopy, and 90.8% would repeat the procedure. No complications occurred. CONCLUSIONS: CS is a safe, feasible, accurate and highly acceptable less-invasive tool for monitoring EoE. Its implementation could improve care pathways, reducing the need for repeated endoscopic biopsies while maintaining diagnostic reliability, with potential to reduce service burden, carbon emissions and improve patient experience. TRIAL REGISTRATION: CoSiE: IRAS number: 314770; ClinicalTrials.gov identifier: NCT06501274; QuBiE: UK Clinical Trial registry identifier: ISRCTN14071734; Trial number: 10083253.

Alimentary Pharmacology & Therapeutics
Nottingham University Hospitals NHS Trust (GB), University of Nottingham (GB), County Durham and Darlington NHS Foundation Trust (GB), NIHR Nottingham Digestive Diseases Biomedical Research Unit (GB), East and North Hertfordshire NHS Trust (GB), Nottingham Biomedical Research Centre (GB), Cytel (United States) (US)
Openalex Percentile: Top 11%
Eosinophilic Esophagitis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon