Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI

Abstract Background Virtual contrast-enhanced (vCE) breast MRI is a deep learning approach for generating contrast-like images from non-contrast acquisitions. As diffusion-weighted imaging (DWI) has emerged as a major contributor to enhancement synthesis, understanding the influence of DWI-related image artifacts is important for the robustness and potential clinical implementation of AI-based contrast-free imaging approaches. We evaluated the robustness of a pix2pix-based vCE synthesis model to artifact-contaminated DWI during training and inference. Materials and methods This IRB-approved, retrospective study included 1,974 multiparametric breast MRI examinations (mean age: 49 years) acquired with two clinical routine 3T MRI scanners (2017–2022). High b-value (b = 1500 s/mm 2 ) DWI images were automatically classified for high-intensity (HI) and low-intensity (LI) artifacts using a pretrained neural network. A pix2pix 2D-GAN was trained either after excluding artifact-affected slices (vCE-clean) or using all available slices (vCE-all). Performance was evaluated using image similarity metrics, lesion-based analysis, reader assessment, and correlation of artifact scores with reconstruction errors. Results Excluding artifact-affected slices during training resulted in a small but statistically significant increase in whole-image structural similarity index (SSIM) with small effect size ( vCE-all 0.843 ± 0.034; vCE-clean 0.849 ± 0.031, p < 0.001, d av = 0.20). However, lesion-based metrics and qualitative ratings of lesion enhancement and image quality were comparable between models. During Inference, strong LI DWI artifacts were associated with higher lesion-based errors. Conclusion Controlling for artifacts on diffusion weighted imaging (DWI) during vCE training only minorly influenced technical metrics but not perceived image quality/lesion enhancement. In contrast, severe signal-loss artifacts during inference impaired local performance, highlighting the importance of image quality control during potential deployment.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-11-03
DOI
https://doi.org/10.1186/s12880-026-02996-8
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI

Florian Knöll, Frederik Bernd Laun, Luise Brock, Evelyn Wenkel et al.
BMC Medical Imaging
MRI in cancer diagnosis
article

Influence of dominant sequence artifacts on generative AI for virtual contrast-enhancement in breast MRI

Florian Knöll, Frederik Bernd Laun, Luise Brock, Evelyn Wenkel, Sebastian Bickelhaupt, Lorenz A. Kapsner, Tri-Thien Nguyen, Sabine Ohlmeyer, Hannes Schreiter, Michael Uder, Marie Metz, Shirin Heidarikahkesh, Ameya Markale, Aju George, Julian Pfann Hossbach
article en

Abstract

Abstract Background Virtual contrast-enhanced (vCE) breast MRI is a deep learning approach for generating contrast-like images from non-contrast acquisitions. As diffusion-weighted imaging (DWI) has emerged as a major contributor to enhancement synthesis, understanding the influence of DWI-related image artifacts is important for the robustness and potential clinical implementation of AI-based contrast-free imaging approaches. We evaluated the robustness of a pix2pix-based vCE synthesis model to artifact-contaminated DWI during training and inference. Materials and methods This IRB-approved, retrospective study included 1,974 multiparametric breast MRI examinations (mean age: 49 years) acquired with two clinical routine 3T MRI scanners (2017–2022). High b-value (b = 1500 s/mm 2 ) DWI images were automatically classified for high-intensity (HI) and low-intensity (LI) artifacts using a pretrained neural network. A pix2pix 2D-GAN was trained either after excluding artifact-affected slices (vCE-clean) or using all available slices (vCE-all). Performance was evaluated using image similarity metrics, lesion-based analysis, reader assessment, and correlation of artifact scores with reconstruction errors. Results Excluding artifact-affected slices during training resulted in a small but statistically significant increase in whole-image structural similarity index (SSIM) with small effect size ( vCE-all 0.843 ± 0.034; vCE-clean 0.849 ± 0.031, p < 0.001, d av = 0.20). However, lesion-based metrics and qualitative ratings of lesion enhancement and image quality were comparable between models. During Inference, strong LI DWI artifacts were associated with higher lesion-based errors. Conclusion Controlling for artifacts on diffusion weighted imaging (DWI) during vCE training only minorly influenced technical metrics but not perceived image quality/lesion enhancement. In contrast, severe signal-loss artifacts during inference impaired local performance, highlighting the importance of image quality control during potential deployment.

BMC Medical ImagingVol. 26(1)
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Institute of Computer Science (PL), Universitätsklinikum Erlangen (DE), Polish Academy of Sciences (PL)
Openalex Percentile: Top 14%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.