OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation

Abstract Objective: Single-photon emission computed tomography (SPECT) simulations must resolve collimator transport, detector energy deposition, and low-efficiency projection formation within one model. General transport codes leave users to build the imaging components, whereas dedicated SPECT codes offer efficient camera models with less freedom to represent new systems. We developed OpenTOPAS-SPECT to bring projection-domain SPECT simulation into the declarative parameter-file workflow of OpenTOPAS. Approach: We added parametric parallel-hole, converging, pinhole, multi-pinhole, and slit-slat collimators; sodium-iodide and cadmium-zinc-telluride detector configurations; energy-resolved and forced-detection scorers; native decay-chain sources; and an evidence-graded library of 14 camera presets. We tested preset construction, multi-view consistency, and variance reduction, and benchmarked projection-domain quantities against measured, independent-code, and analytic references. Main results: At 140.5 keV and 10 cm from the collimator face, the Siemens Symbia low-energy high-resolution configuration gave 7.49 × 10-5 counts per decay, or 0.82 of the measured 9.1 × 10-5. GE collimator sensitivities were 1.08 to 1.15× the SIMIND range midpoints, while the 364.5 keV low-to-high-energy sensitivity ratio was 59.5 versus 67.7. Planar point-spread widths were 4% to 9% below analytic geometric resolution from 5 to 30 cm. In this Symbia LEHR point-source geometry, forced detection reached matched precision 6.9× faster than full transport and reproduced its absolute sensitivity to 1% without calibration. Across 20 configurations (five collimators, 113 keV to 1 MeV), forced detection stayed within 4% of full transport while septa carried up to a fifth of the signal, but fell 7% to 25% below it where they carried 25% or more. The release-gating suite ran all 23 example decks and built all 14 presets. Significance: OpenTOPAS-SPECT provides reusable SPECT components within the OpenTOPAS parameter system, with bounded projection-domain benchmarks for the first stable public release. The evidence supports the tested configurations and observables; reconstructed-image accuracy and broader system coverage remain untested.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-03
DOI
https://doi.org/10.1088/1361-6560/aebd36
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation

Víctor Valladolid Onecha, Alejandro Bertolet
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

OpenTOPAS-SPECT: an extension for full-physics clinical and preclinical SPECT simulation

Víctor Valladolid Onecha, Alejandro Bertolet
article en

Abstract

Abstract Objective: Single-photon emission computed tomography (SPECT) simulations must resolve collimator transport, detector energy deposition, and low-efficiency projection formation within one model. General transport codes leave users to build the imaging components, whereas dedicated SPECT codes offer efficient camera models with less freedom to represent new systems. We developed OpenTOPAS-SPECT to bring projection-domain SPECT simulation into the declarative parameter-file workflow of OpenTOPAS. Approach: We added parametric parallel-hole, converging, pinhole, multi-pinhole, and slit-slat collimators; sodium-iodide and cadmium-zinc-telluride detector configurations; energy-resolved and forced-detection scorers; native decay-chain sources; and an evidence-graded library of 14 camera presets. We tested preset construction, multi-view consistency, and variance reduction, and benchmarked projection-domain quantities against measured, independent-code, and analytic references. Main results: At 140.5 keV and 10 cm from the collimator face, the Siemens Symbia low-energy high-resolution configuration gave 7.49 × 10-5 counts per decay, or 0.82 of the measured 9.1 × 10-5. GE collimator sensitivities were 1.08 to 1.15× the SIMIND range midpoints, while the 364.5 keV low-to-high-energy sensitivity ratio was 59.5 versus 67.7. Planar point-spread widths were 4% to 9% below analytic geometric resolution from 5 to 30 cm. In this Symbia LEHR point-source geometry, forced detection reached matched precision 6.9× faster than full transport and reproduced its absolute sensitivity to 1% without calibration. Across 20 configurations (five collimators, 113 keV to 1 MeV), forced detection stayed within 4% of full transport while septa carried up to a fifth of the signal, but fell 7% to 25% below it where they carried 25% or more. The release-gating suite ran all 23 example decks and built all 14 presets. Significance: OpenTOPAS-SPECT provides reusable SPECT components within the OpenTOPAS parameter system, with bounded projection-domain benchmarks for the first stable public release. The evidence supports the tested configurations and observables; reconstructed-image accuracy and broader system coverage remain untested.

Physics in Medicine and Biology
Massachusetts General Hospital (US)
Openalex Percentile: Top 14%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon