A Hybrid Compensation System Combining a Parallel LC Filter and a Shunt Active Power Filter Using Load-Conductance-Signal Control

This paper investigates a hybrid active power filter (HAPF) composed of a shunt active power filter (SAPF) connected in parallel with an LC passive filter designed according to the Currents’ Physical Components (CPC) theory. Importantly, the SAPF operates using a load-conductance-signal control strategy in which the DC-link capacitor voltage is not regulated around a fixed reference value. Instead, it reflects the instantaneous power balance within the source-filter-load system and is used to generate the source-current reference. The present study focuses on maintaining the distortion of this signal at the lowest possible level, since its quality directly affects the performance of the filtering system. The hybrid configuration reduced source-current THD to approximately 2% in all phases, compared with values of up to 14% for stand-alone SAPF operation. Moreover, the THD of the DC-link voltage decreased from 85% to 4%. The results demonstrate that CPC-based passive balancing combined with conductance-controlled active filtering improves both compensation effectiveness and SAPF operating conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-03
DOI
https://doi.org/10.3390/en19215245
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Compensation System Combining a Parallel LC Filter and a Shunt Active Power Filter Using Load-Conductance-Signal Control

Andrzej Szromba
Energies
Power Quality and Harmonics
article

A Hybrid Compensation System Combining a Parallel LC Filter and a Shunt Active Power Filter Using Load-Conductance-Signal Control

Andrzej Szromba
article en

Abstract

This paper investigates a hybrid active power filter (HAPF) composed of a shunt active power filter (SAPF) connected in parallel with an LC passive filter designed according to the Currents’ Physical Components (CPC) theory. Importantly, the SAPF operates using a load-conductance-signal control strategy in which the DC-link capacitor voltage is not regulated around a fixed reference value. Instead, it reflects the instantaneous power balance within the source-filter-load system and is used to generate the source-current reference. The present study focuses on maintaining the distortion of this signal at the lowest possible level, since its quality directly affects the performance of the filtering system. The hybrid configuration reduced source-current THD to approximately 2% in all phases, compared with values of up to 14% for stand-alone SAPF operation. Moreover, the THD of the DC-link voltage decreased from 85% to 4%. The results demonstrate that CPC-based passive balancing combined with conductance-controlled active filtering improves both compensation effectiveness and SAPF operating conditions.

EnergiesVol. 19(21)
Cracow University of Technology (PL)
Openalex Percentile: Top 26%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A Hybrid Compensation System Combining a Parallel LC Filter and a Shunt Active Power Filter Using Load-Conductance-Signal Control — Andrzej Szromba · Energies (2026) | TGRS Research Map | TGRS