Biomechanical responses and scleral reinforcement across staphyloma subtypes in pathologic myopia: a finite element analysis

Objective Posterior scleral staphyloma (PSS) is a common complication of pathologic myopia and may lead to deformation of posterior pole structures, including macula and lamina cribrosa (LC). Different types of PSS exhibit distinct structural features and corresponding patterns of fundus damage. Prior studies have defined PSS morphological classification and its association with fundus lesions, yet the biomechanical mechanisms of subtype-specific damage and quantitative evaluation of posterior scleral reinforcement (PSR) remain unaddressed. Therefore, this study explored posterior pole biomechanical responses in PSS and PSR efficacy to guide clinical management. Methods Whole-eye finite element models were established incorporating five Curtin-classified PSS subtypes and three axial lengths. Key posterior pole biomechanical parameters related to lamina cribrosa displacement and macular strain were extracted. PSR was then simulated using the reinforcing strip with varied elastic moduli to compare pre- and post-operative mechanical responses. Results PSS subtype and staphyloma depth-radius morphological combinations influenced biomechanical responses of posterior pole structures. Type I (wide macular) PSS demonstrated the largest LC displacements, with mean LC_X_DistMean of 0.0215 ± 0.0133 mm and LC_Y_DistMean of 0.0188 ± 0.0138 mm. HSR_RM_0.04 was lower in the PSR models (from 19.45% to 3.58%), indicating reduced macular high-strain exposure. Higher strip modulus further decreased HSR_RM_0.04 across all five PSS subtypes. Conclusion PSS subtype-specific geometries showed the largest effect within the tested parameter ranges, while the depth-radius configuration accounted for subtype-specific variations in macular strain patterns. PSR simulations indicated reduced IOP-driven HSR_RM_0.04, enhanced by higher strip modulus with the strip configuration used in this study. These findings support morphology-tailored, in silico comparisons within static idealized models and warrant prospective clinical validation.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-02
DOI
https://doi.org/10.3389/fbioe.2026.1948781
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical responses and scleral reinforcement across staphyloma subtypes in pathologic myopia: a finite element analysis

Jifeng Ren, Xiuqing Qian, Li-ya Qiao, Yanqing Wang et al.
2 links
Frontiers in Bioengineering and Biotechnology
Ophthalmology and Visual Impairment Studies
article

Biomechanical responses and scleral reinforcement across staphyloma subtypes in pathologic myopia: a finite element analysis

Jifeng Ren, Xiuqing Qian, Li-ya Qiao, Yanqing Wang, Xiaoxia Li
article en

Abstract

Objective Posterior scleral staphyloma (PSS) is a common complication of pathologic myopia and may lead to deformation of posterior pole structures, including macula and lamina cribrosa (LC). Different types of PSS exhibit distinct structural features and corresponding patterns of fundus damage. Prior studies have defined PSS morphological classification and its association with fundus lesions, yet the biomechanical mechanisms of subtype-specific damage and quantitative evaluation of posterior scleral reinforcement (PSR) remain unaddressed. Therefore, this study explored posterior pole biomechanical responses in PSS and PSR efficacy to guide clinical management. Methods Whole-eye finite element models were established incorporating five Curtin-classified PSS subtypes and three axial lengths. Key posterior pole biomechanical parameters related to lamina cribrosa displacement and macular strain were extracted. PSR was then simulated using the reinforcing strip with varied elastic moduli to compare pre- and post-operative mechanical responses. Results PSS subtype and staphyloma depth-radius morphological combinations influenced biomechanical responses of posterior pole structures. Type I (wide macular) PSS demonstrated the largest LC displacements, with mean LC_X_DistMean of 0.0215 ± 0.0133 mm and LC_Y_DistMean of 0.0188 ± 0.0138 mm. HSR_RM_0.04 was lower in the PSR models (from 19.45% to 3.58%), indicating reduced macular high-strain exposure. Higher strip modulus further decreased HSR_RM_0.04 across all five PSS subtypes. Conclusion PSS subtype-specific geometries showed the largest effect within the tested parameter ranges, while the depth-radius configuration accounted for subtype-specific variations in macular strain patterns. PSR simulations indicated reduced IOP-driven HSR_RM_0.04, enhanced by higher strip modulus with the strip configuration used in this study. These findings support morphology-tailored, in silico comparisons within static idealized models and warrant prospective clinical validation.

Frontiers in Bioengineering and BiotechnologyVol. 14
Beijing Tongren Hospital (CN), Capital Medical University (CN), Beijing Shijitan Hospital (CN)
Good health and well-being
Openalex Percentile: Top 13%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon