Mechanism-based numerical investigation of temperature- and corrosion-related local distresses in a long-span PC box-girder bridge: A case study

Long-span prestressed concrete (PC) continuous rigid-frame bridges may develop persistent local distress under long-term traffic loading and environmental exposure. Temperature- and corrosion-related mechanisms can contribute to recurrent local deterioration. This paper presents a case-based failure analysis of two representative distress modes observed in a 28-year-old in-service long-span PC continuous rigid-frame bridge: longitudinal cracking at the flange-web chamfers and corrosion-induced concrete spalling at the flange edges. Using field inspection data, long-term monitoring and load-test records, available material information, and nonlinear finite element analysis, three complementary mechanism-specific models were developed with the concrete damaged plasticity (CDP) constitutive model. The models examine the roles of long-term deformation, temperature gradients, corrosion-induced expansion, and steel-concrete thermal mismatch. The numerical damage patterns show spatial consistency with the observed distress. Model 1 shows that a positive temperature gradient extends the high-tensile-stress zone along the chamfer when applied to the deformation-induced stress state. Model 2 reproduces progressive cover damage under idealized corrosion expansion, while Model 3 produces a connected interfacial high-damage path in the 37.5 K unconfined thermal-mismatch case. Together, the field evidence and numerical results support a plausible deterioration pathway linking chamfer cracking, environmental ingress, and flange-edge spalling, providing a basis for targeted durability assessment and maintenance.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2026-11-01
DOI
https://doi.org/10.1016/j.cscm.2026.e06675
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanism-based numerical investigation of temperature- and corrosion-related local distresses in a long-span PC box-girder bridge: A case study

Benniu Zhang, Jigang Yu, Fupeng Zhou, Liangshuo Zhang et al.
Case Studies in Construction Materials
Concrete Corrosion and Durability
article

Mechanism-based numerical investigation of temperature- and corrosion-related local distresses in a long-span PC box-girder bridge: A case study

Benniu Zhang, Jigang Yu, Fupeng Zhou, Liangshuo Zhang, Jinglin Pan, Haonan Xia, Hongmei Cui, Xiaodong Wu
article en

Abstract

Long-span prestressed concrete (PC) continuous rigid-frame bridges may develop persistent local distress under long-term traffic loading and environmental exposure. Temperature- and corrosion-related mechanisms can contribute to recurrent local deterioration. This paper presents a case-based failure analysis of two representative distress modes observed in a 28-year-old in-service long-span PC continuous rigid-frame bridge: longitudinal cracking at the flange-web chamfers and corrosion-induced concrete spalling at the flange edges. Using field inspection data, long-term monitoring and load-test records, available material information, and nonlinear finite element analysis, three complementary mechanism-specific models were developed with the concrete damaged plasticity (CDP) constitutive model. The models examine the roles of long-term deformation, temperature gradients, corrosion-induced expansion, and steel-concrete thermal mismatch. The numerical damage patterns show spatial consistency with the observed distress. Model 1 shows that a positive temperature gradient extends the high-tensile-stress zone along the chamfer when applied to the deformation-induced stress state. Model 2 reproduces progressive cover damage under idealized corrosion expansion, while Model 3 produces a connected interfacial high-damage path in the 37.5 K unconfined thermal-mismatch case. Together, the field evidence and numerical results support a plausible deterioration pathway linking chamfer cracking, environmental ingress, and flange-edge spalling, providing a basis for targeted durability assessment and maintenance.

Case Studies in Construction Materials
Chongqing Telecommunication Polytechnic College (CN), Chongqing Jiaotong University (CN)
Openalex Percentile: Top 19%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon