Agreement of wired and wireless electronic apex locator measurements with CBCT-derived measurements in teeth with large periapical lesions and intracanal exudation: a prospective comparative clinical study

Working length determination may be challenging in teeth with large periapical lesions and intracanal exudation, conditions that may influence the performance of electronic apex locators (EALs). This study evaluated the repeatability of working length measurements obtained with two wired EALs (Propex Pixi and iPex II) and two wireless EALs (AirPex and the Bluetooth-enabled Wirele-X), as well as their agreement with cone-beam computed tomography (CBCT)-derived measurements under these clinical conditions.This study evaluated the repeatability of working length measurements obtained with three wired EALs (Propex Pixi, iPex II, and AirPex) and one Bluetooth-enabled wireless EAL (Wirele-X), as well as their agreement with cone-beam computed tomography (CBCT)-derived measurements under these clinical conditions. Seventy-one single-rooted, single-canal teeth from 42 patients with large periapical lesions and intracanal exudation were included. Working length was determined using four EALs: Propex Pixi, iPex II, AirPex, and Wirele-X. Three consecutive measurements were obtained with each device. CBCT measurements were performed twice, 7 days apart, by a blinded oral and maxillofacial radiologist. Repeatability was assessed using intraclass correlation coefficients (ICCs), and agreement with CBCT-derived measurements was evaluated using Bland–Altman analysis. Absolute deviations among devices were compared, and the proportions of measurements within ± 0.5 mm and ± 1.0 mm of the CBCT-derived measurements were assessed using Cochran’s Q test. All EALs demonstrated excellent repeatability (ICC ≥ 0.999). Although small statistically significant differences were observed among repeated measurements for AirPex and Wirele-X, their magnitude was clinically negligible. Absolute deviations from CBCT-derived measurements did not differ significantly among the four devices ( p = 0.554). Bland–Altman limits of agreement were approximately − 2.7 to + 2.6 mm. The proportions of measurements within ± 0.5 mm were 59.15% for Propex Pixi, 60.56% for iPex II, 61.97% for AirPex, and 61.97% for Wirele-X ( p = 0.927). Within ± 1.0 mm, the corresponding rates were 91.55%, 91.55%, 92.96%, and 90.14%, respectively ( p = 0.820). All four EALs demonstrated high measurement repeatability, with no statistically significant differences in their agreement with CBCT-derived working length measurements. However, the relatively wide Bland–Altman limits of agreement indicate that substantial discrepancies may occur in individual teeth despite the high repeatability of the devices.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-11-03
DOI
https://doi.org/10.1186/s12903-026-10377-4
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement of wired and wireless electronic apex locator measurements with CBCT-derived measurements in teeth with large periapical lesions and intracanal exudation: a prospective comparative clinical study

Yakup Üstün, Aykagan Cukurluoglu, Ilyas Posma, Beyza Yalçıntaş Erbulut
BMC Oral Health
Dental Radiography and Imaging
article

Agreement of wired and wireless electronic apex locator measurements with CBCT-derived measurements in teeth with large periapical lesions and intracanal exudation: a prospective comparative clinical study

Yakup Üstün, Aykagan Cukurluoglu, Ilyas Posma, Beyza Yalçıntaş Erbulut
article en

Abstract

Working length determination may be challenging in teeth with large periapical lesions and intracanal exudation, conditions that may influence the performance of electronic apex locators (EALs). This study evaluated the repeatability of working length measurements obtained with two wired EALs (Propex Pixi and iPex II) and two wireless EALs (AirPex and the Bluetooth-enabled Wirele-X), as well as their agreement with cone-beam computed tomography (CBCT)-derived measurements under these clinical conditions.This study evaluated the repeatability of working length measurements obtained with three wired EALs (Propex Pixi, iPex II, and AirPex) and one Bluetooth-enabled wireless EAL (Wirele-X), as well as their agreement with cone-beam computed tomography (CBCT)-derived measurements under these clinical conditions. Seventy-one single-rooted, single-canal teeth from 42 patients with large periapical lesions and intracanal exudation were included. Working length was determined using four EALs: Propex Pixi, iPex II, AirPex, and Wirele-X. Three consecutive measurements were obtained with each device. CBCT measurements were performed twice, 7 days apart, by a blinded oral and maxillofacial radiologist. Repeatability was assessed using intraclass correlation coefficients (ICCs), and agreement with CBCT-derived measurements was evaluated using Bland–Altman analysis. Absolute deviations among devices were compared, and the proportions of measurements within ± 0.5 mm and ± 1.0 mm of the CBCT-derived measurements were assessed using Cochran’s Q test. All EALs demonstrated excellent repeatability (ICC ≥ 0.999). Although small statistically significant differences were observed among repeated measurements for AirPex and Wirele-X, their magnitude was clinically negligible. Absolute deviations from CBCT-derived measurements did not differ significantly among the four devices ( p = 0.554). Bland–Altman limits of agreement were approximately − 2.7 to + 2.6 mm. The proportions of measurements within ± 0.5 mm were 59.15% for Propex Pixi, 60.56% for iPex II, 61.97% for AirPex, and 61.97% for Wirele-X ( p = 0.927). Within ± 1.0 mm, the corresponding rates were 91.55%, 91.55%, 92.96%, and 90.14%, respectively ( p = 0.820). All four EALs demonstrated high measurement repeatability, with no statistically significant differences in their agreement with CBCT-derived working length measurements. However, the relatively wide Bland–Altman limits of agreement indicate that substantial discrepancies may occur in individual teeth despite the high repeatability of the devices.

BMC Oral Health
Erciyes University (TR)
Good health and well-being
Openalex Percentile: Top 12%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon