Development of Lyophilized Control Material for G6PD Quantitative Point-of-Care Testing

G6PD deficiency affects approximately 500 million people globally, necessitating enzymatic screening before antimalarial treatment to prevent drug-induced hemolysis. Despite the expansion of quantitative point-of-care testing (POCT), standardized lyophilized controls are still limited. This study aims to develop these materials to ensure diagnostic accuracy and support EQA program. Control materials were prepared from G6PD-normal and deficient packed red blood cells (PRBCs). PRBCs were washed and mixed with 5% (w/v) sucrose at the optimized 1:5, 1:10, 1:15 and 1:20 ratios. G6PD activity and hemoglobin (Hb) levels were quantified using the STANDARD™ G6PD test. Stability was evaluated at 4 and -20°C through 6 months. The 1:20 formulation demonstrated optimal reconstitution and clear phenotype differentiation. At 4°C, G6PD activity of G6PD normal control materials remained stable for 1 month followed by a fluctuation below the normal threshold at month 2 (3.9 U/g Hb) while at -20°C, it maintained stability for up to 6 months, despite a gradual decline to 4.0 U/g Hb. Whereas the G6PD deficient control materials exhibited remarkable stability at both temperatures. In addition, Hb levels appeared relatively stable across all tested conditions throughout the 6-month period. In conclusion, lyophilized G6PD control materials with 5% sucrose solution at a 1:20 ratio are suitable for quantitative POCT. For long-term stability, -20°C storage is recommended. This material provides a robust foundation for developing EQA programs compliant with ISO/IEC 17043:2023, ensuring reliable G6PD quantitative Point-of-Care testing.

Authors

Institutions

Publication Details

Journal
Natural and Life Sciences Communications
Published
2026-11-02
DOI
https://doi.org/10.12982/nlsc.2027.010
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Lyophilized Control Material for G6PD Quantitative Point-of-Care Testing

Manoo Punyamung, Panida Pongpunyayuen, Chedtapak Ruengdit, Sakorn Pornprasert et al.
Natural and Life Sciences Communications
Clinical Laboratory Practices and Quality Control
article

Development of Lyophilized Control Material for G6PD Quantitative Point-of-Care Testing

Manoo Punyamung, Panida Pongpunyayuen, Chedtapak Ruengdit, Sakorn Pornprasert, Wachiraporn Mongkham, Thanatip Chaisonying, Nathaphon Cheammanee
article en

Abstract

G6PD deficiency affects approximately 500 million people globally, necessitating enzymatic screening before antimalarial treatment to prevent drug-induced hemolysis. Despite the expansion of quantitative point-of-care testing (POCT), standardized lyophilized controls are still limited. This study aims to develop these materials to ensure diagnostic accuracy and support EQA program. Control materials were prepared from G6PD-normal and deficient packed red blood cells (PRBCs). PRBCs were washed and mixed with 5% (w/v) sucrose at the optimized 1:5, 1:10, 1:15 and 1:20 ratios. G6PD activity and hemoglobin (Hb) levels were quantified using the STANDARD™ G6PD test. Stability was evaluated at 4 and -20°C through 6 months. The 1:20 formulation demonstrated optimal reconstitution and clear phenotype differentiation. At 4°C, G6PD activity of G6PD normal control materials remained stable for 1 month followed by a fluctuation below the normal threshold at month 2 (3.9 U/g Hb) while at -20°C, it maintained stability for up to 6 months, despite a gradual decline to 4.0 U/g Hb. Whereas the G6PD deficient control materials exhibited remarkable stability at both temperatures. In addition, Hb levels appeared relatively stable across all tested conditions throughout the 6-month period. In conclusion, lyophilized G6PD control materials with 5% sucrose solution at a 1:20 ratio are suitable for quantitative POCT. For long-term stability, -20°C storage is recommended. This material provides a robust foundation for developing EQA programs compliant with ISO/IEC 17043:2023, ensuring reliable G6PD quantitative Point-of-Care testing.

Natural and Life Sciences CommunicationsVol. 26(1)
Chiang Mai University (TH)
Good health and well-being
Openalex Percentile: Top 14%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Development of Lyophilized Control Material for G6PD Quantitative Point-of-Care Testing — Manoo Punyamung, Panida Pongpunyayuen, et al. · Natural and Life Sciences Communications (2026) | TGRS Research Map | TGRS