Evaluating the impact of a living wall on the heating and cooling for a single-storey commercial building

This study evaluates the thermal performance and transient heat transfer characteristics of an experimental modular living wall (LW) compared to a bare control wall (CW) on a single-storey, uninsulated commercial building in Adelaide, South Australia. A full-scale 7.2 m 2 vertical greenery system (VGS) was retrofitted onto a 220 mm west-facing solid double-brick facade and monitored continuously for over 12 months. To ensure high-precision data collection, the experimental setup was instrumented with post-calibrated Type K thermocouples (with a relative error of ± 0.5 °C) to measure surface temperatures, alongside DS1923 iButtons housed in louvred radiation shields placed at distances of 400 mm, 700 mm, and 1000 mm to monitor ambient dry-bulb temperature and relative humidity. To bridge the gap between raw surface temperature reductions and actual building energy performance, a one-dimensional (1-D) transient finite-difference unsteady conduction model was developed to solve conductive heat flux (Q) at iterative 7.5-minute timesteps. Statistical analyses using independent sample T-tests confirmed significant ( p < 0.05) seasonal thermal buffering. During an extreme heatwave day (ambient 46.4 °C), the LW reduced peak external surface temperatures by 26.6 °C and delayed the thermal peak by 1 h and 45 min. Thermodynamic modelling demonstrated that the VGS physically reduced cumulative summer heat gain by 48% (saving 19.5 kWh/m 2 ) and winter heat loss by 21% (saving 2.5 kWh/m 2 ). These empirical and numerical findings provide robust quantification of vertical greenery as a passive building envelope retrofit, offering critical validation data for modern dynamic energy modelling and urban microclimate simulations.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-11-02
DOI
https://doi.org/10.1016/j.tsep.2026.104976
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the impact of a living wall on the heating and cooling for a single-storey commercial building

Simon Beecham, Darrien Yau Seng Mah, Martin Belusko, Rosmina A. Bustami et al.
Thermal Science and Engineering Progress
Urban Heat Island Mitigation
article

Evaluating the impact of a living wall on the heating and cooling for a single-storey commercial building

Simon Beecham, Darrien Yau Seng Mah, Martin Belusko, Rosmina A. Bustami, James D. Ward, Ahmad A. M. Khairulzaim, Norazlina Bateni
article en

Abstract

This study evaluates the thermal performance and transient heat transfer characteristics of an experimental modular living wall (LW) compared to a bare control wall (CW) on a single-storey, uninsulated commercial building in Adelaide, South Australia. A full-scale 7.2 m 2 vertical greenery system (VGS) was retrofitted onto a 220 mm west-facing solid double-brick facade and monitored continuously for over 12 months. To ensure high-precision data collection, the experimental setup was instrumented with post-calibrated Type K thermocouples (with a relative error of ± 0.5 °C) to measure surface temperatures, alongside DS1923 iButtons housed in louvred radiation shields placed at distances of 400 mm, 700 mm, and 1000 mm to monitor ambient dry-bulb temperature and relative humidity. To bridge the gap between raw surface temperature reductions and actual building energy performance, a one-dimensional (1-D) transient finite-difference unsteady conduction model was developed to solve conductive heat flux (Q) at iterative 7.5-minute timesteps. Statistical analyses using independent sample T-tests confirmed significant ( p < 0.05) seasonal thermal buffering. During an extreme heatwave day (ambient 46.4 °C), the LW reduced peak external surface temperatures by 26.6 °C and delayed the thermal peak by 1 h and 45 min. Thermodynamic modelling demonstrated that the VGS physically reduced cumulative summer heat gain by 48% (saving 19.5 kWh/m 2 ) and winter heat loss by 21% (saving 2.5 kWh/m 2 ). These empirical and numerical findings provide robust quantification of vertical greenery as a passive building envelope retrofit, offering critical validation data for modern dynamic energy modelling and urban microclimate simulations.

Thermal Science and Engineering ProgressVol. 80
University of South Australia (AU), Universiti Malaysia Sarawak (MY)
Affordable and clean energy, Sustainable cities and communities
Openalex Percentile: Top 24%
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon