A smaller preoperative-to-prosthetic center of rotation shift is associated with better range of motion after bony increased-offset reverse shoulder arthroplasty: A retrospective cohort study of 97 patients by the FP-UCBM Shoulder Group

Background Reverse shoulder arthroplasty (RSA) alters the glenohumeral center of rotation (CoR), but the relevance of preoperative-to-prosthetic CoR shift remains unclear. This study evaluated its association with postoperative outcomes after bony increased-offset RSA (BIO-RSA). Methods We retrospectively reviewed 120 patients undergoing BIO-RSA with a 145° onlay humeral stem and a minimum 24-month follow-up; 97 met inclusion criteria. CoR positions were quantified using angular measurements based on reproducible scapular landmarks. Preoperative measurements were obtained from scapular-plane computed tomography reconstructions and postoperative measurements from 2-year true anteroposterior radiographs. ΔCoR was defined as Pre-CoR angle minus Post-CoR angle. Outcomes included visual analog scale pain, Constant–Murley score, Simple Shoulder Test, and active range of motion; associations were assessed using linear-regression and Spearman correlation analyses. Results Each 1° increase in ΔCoR was associated with lower postoperative abduction (−1.13°, p = .028, R 2 = .055) and forward flexion (−0.82°, p = .037, R 2 = .050). Spearman analysis showed a significant association only with abduction (ρ = −0.255, p = .016). No significant associations were observed with pain or functional scores. Conclusion A smaller preoperative-to-prosthetic CoR shift may be associated with greater elevation after BIO-RSA. Given the weak associations, ΔCoR should be interpreted cautiously as a radiographic parameter rather than an independent predictor.

Authors

Institutions

Publication Details

Journal
Shoulder & Elbow
Published
2026-11-01
DOI
https://doi.org/10.1177/17585732261503479
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A smaller preoperative-to-prosthetic center of rotation shift is associated with better range of motion after bony increased-offset reverse shoulder arthroplasty: A retrospective cohort study of 97 patients by the FP-UCBM Shoulder Group

Giovanni Perricone, Michele Paciotti, Rocco Papalia, Edoardo Franceschetti et al.
Shoulder & Elbow
Shoulder Injury and Treatment
article

A smaller preoperative-to-prosthetic center of rotation shift is associated with better range of motion after bony increased-offset reverse shoulder arthroplasty: A retrospective cohort study of 97 patients by the FP-UCBM Shoulder Group

Giovanni Perricone, Michele Paciotti, Rocco Papalia, Edoardo Franceschetti, Mauro Ciuffreda, Antonino De Rosa, Pietro Gregori, Mauro La Bruna, Chiara Capperucci, Piergianni Luigi Di Santo
article en

Abstract

Background Reverse shoulder arthroplasty (RSA) alters the glenohumeral center of rotation (CoR), but the relevance of preoperative-to-prosthetic CoR shift remains unclear. This study evaluated its association with postoperative outcomes after bony increased-offset RSA (BIO-RSA). Methods We retrospectively reviewed 120 patients undergoing BIO-RSA with a 145° onlay humeral stem and a minimum 24-month follow-up; 97 met inclusion criteria. CoR positions were quantified using angular measurements based on reproducible scapular landmarks. Preoperative measurements were obtained from scapular-plane computed tomography reconstructions and postoperative measurements from 2-year true anteroposterior radiographs. ΔCoR was defined as Pre-CoR angle minus Post-CoR angle. Outcomes included visual analog scale pain, Constant–Murley score, Simple Shoulder Test, and active range of motion; associations were assessed using linear-regression and Spearman correlation analyses. Results Each 1° increase in ΔCoR was associated with lower postoperative abduction (−1.13°, p = .028, R 2 = .055) and forward flexion (−0.82°, p = .037, R 2 = .050). Spearman analysis showed a significant association only with abduction (ρ = −0.255, p = .016). No significant associations were observed with pain or functional scores. Conclusion A smaller preoperative-to-prosthetic CoR shift may be associated with greater elevation after BIO-RSA. Given the weak associations, ΔCoR should be interpreted cautiously as a radiographic parameter rather than an independent predictor.

Shoulder & Elbow
Università Campus Bio-Medico (IT), Campus Bio Medico University Hospital (IT)
Openalex Percentile: Top 9%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon